asokatechnologies@gmail.com 09347143789/09949240245

Search This Blog

Wednesday, 8 February 2017

Design of a multilevel inverter with reactive power Control ability for connecting PV cells to the grid


 ABSTRACT:  
With the increasing use of PV cells in power system, optimal utilization of the equipment is an important issue. In these systems the MPPT controller is used to inject the maximum available power from solar energy. During day time that the active power decreases because of low intensity, the inverter is capable of injecting reactive power up to its nominal capacity and this is a chance for reactive power compensation. In this paper the aim is to propose a control method for injecting the maximum active power and if possible, the reactive power. In addition, a low pass filter is suggested to solve the problem of current fluctuations in case of unbalanced load. Simulation results on a typical system in MATLAB indicate proper performance of the presented method.

KEYWORDS:

1.      NPC inverter
2.      Maximum Power Point Tracking (MPPT)
3.      Photovoltaic cell (PV)
4.      PI current control
5.      Space vector pulse width modulation (SVPWM)

SOFTWARE: MATLAB/SIMULINK

BLOCK DIAGRAM:



Fig1. Studied system for injecting power to the grid and local load

 EXPECTED SIMULATION RESULTS:


Figure2. output active and reactive power of the inverter


Figure3. THD of injected current to the grid in no-load condition


Figure4. Injecting active power in no-load condition and low intensity of light


Figure5. load increase at t=0.5s and its effects on active and reactive power

Figure6. Injected voltage and current to the grid and the effect of inductive load on current

Figure7. Analyzing THD of injected current to the grid in PeL=50kw and PQL=30kvar condition

Figure8. Power increment in two levels: a. at t=0.5s and b. at t=0.7s

Figure9. Output power of inverter and the grid

Figure10. Output voltage and current after using filter and limiter

Figure11. THD of circuit when PeL=50kw and PQL=30kvar and using filter and limiter

CONCLUSION:

In this paper a control strategy is proposed for current control of PV inverter that control s maximum generated active power and reactive power compensation of local load simultaneously .The main idea is to utilize inverter for reactive power injection during active power decrement .using a low pass filter and power limiter in control system , produced oscillations due to unbalanced load is eliminated and inverter works in safe condition simulation results show the proposed method to be viable in controlling inverter

REFERENCES:
 [1] Chung-ChuanHou,Chih-Chung Shih, Po-Tai Cheng,Ahmet M. Hava, Common-Mode Voltage Reduction Pulsewidth
Modulation Techniques for Three-Phase Grid-Connected Converters , IEEE TRANSACTIONS ON POWER ELECTRONICS, VOL. 28, NO. 4, APRIL 2013
[2] GeorgiosTsengenes, Thomas Nathenas, Georgios Adamidis,” A three-level space vector modulated grid connected inverter with control scheme based on instantaneous power theory", Simulation Modelling Practice and Theory 25 (2012) 134–147
[3] S. Kouro, K. Asfaw, R. Goldman, R. Snow, B. Wu, and J. Rodríguez, NPC Multilevel Multistring Topology for Larg Scale Grid Connected Photovoltaic Systems,2010 2nd IEEE International Symposium on Power Electronics for Distributed Generation Systems
[4] Georgios A. Tsengenes, Georgios A. Adamidis, Study of a Simple Control Strategy for Grid
Connected VSI Using SVPWM and p-q Theory,XIX International Conference on Electrical Machines - ICEM 2010, Rome
[5] César Trujillo Rodríguez, David Velasco de la Fuente, Gabriel Garcerá, Emilio Figueres, and Javier A. Gua can eme Moreno,Reconfigurable Control Scheme for a PV


Saturday, 4 February 2017

Full-Soft-Switching High Step-Up Bidirectional Isolated Current-Fed Push-Pull DC-DC Converter for Battery Energy Storage Applications



ABSTRACT:

This paper presents a novel bidirectional current fed push-pull DC-DC converter topology with galvanic isolation. The control algorithm proposed enables full-soft-switching of all transistors in a wide range of input voltage and power with no requirement for snubbers or resonant switching. The converter features an active voltage doubler rectifier controlled by the switching sequence synchronous to that of the input-side switches. As a result, full-soft-switching operation at a fixed switching frequency is achieved. Operation principle for the energy transfer in both directions is described, followed by verification with a 300 W experimental prototype. The converter has considerably higher voltage step-up performance than traditional current-fed converters Experimental results obtained are in good agreement with the theoretical steady-state analysis.
KEYWORDS:

1.      Current-fed dc-dc converter
2.       Bidirectional converter
3.      Soft-switching
4.       ZVS
5.       ZCS
6.      Push-pull converter
7.      Switching control method
8.       Naturally clamped

SOFTWARE: MATLAB/SIMULINK

CIRCUIT DIAGRAM:


Fig. 1. Full-soft-swithicng CF push-pull converter proposed.

EXPECTED SIMULATION RESULTS:


Fig. 2. Experimental current and voltage waveforms of the switch S1.1



Fig. 3. Experimental current and voltage waveforms of the switch S1.2.



Fig. 4. Experimental current and voltage waveforms of the switch S4.

CONCLUSION:
A novel bidirectional current-fed push-pull converter with galvanic isolation was introduced. It features full-soft switching operation of all semiconductor components, while its DC voltage gain is higher than in traditional current-fed converters due to the utilization of the circulating energy for the input voltage step-up. As a result, it does not suffer from short intervals of energy transfer from the input side to the output side since at least half of the switching period is dedicated for this. Moreover, it does not require any clamping circuits, since the novel control algorithm features natural clamping of the switches at the current-fed side. Despite a relatively high number of semiconductor components, it shows the peak efficiency of 96.3%, which does not depend on the energy transfer direction for the corresponding operating point. Soft-switching operation with continuous current at the current fed side makes the converter proposed suitable for residential battery energy storage systems. Further research will be directed towards experimental verification of the converter performance with a lithium iron phosphate battery.

REFERENCES:

[1] F. Blaabjerg, and D.M. Ionel, "Renewable Energy Devices and Systems – State-of-the-Art Technology, Research and Development, Challenges and Future Trends," Electric Power Components and Systems, vol.43, no.12, pp.1319-1328, 2015.
[2] C, Heymans, S, B. Walker, S. B. Young, M. Fowler, "Economic analysis of second use electric vehicle batteries for residential energy storage and load-levelling," Energy Policy, vol. 71, pp. 22-30, Aug. 2014.
[3] J. Weniger, T. Tjaden, V. Quaschning, "Sizing of Residential PV Battery Systems," Energy Procedia, vol. 46, pp. 78-87,2014.
[4] S. J. Chiang, K. T. Chang and C. Y. Yen, "Residential photovoltaic energy storage system," IEEE Trans. Ind. Electron., vol. 45, no. 3, pp. 385-394, Jun 1998.
[5] S. X. Chen, H. B. Gooi and M. Q. Wang, "Sizing of Energy Storage for Microgrids," IEEE Trans. Smart Grid, vol. 3, no. 1, pp. 142-151, 2012.


Modeling and Analysis of 3-Phase VSI using SPWM Technique for Grid Connected Solar PV System


ABSTRACT:
Solar energy is one of the most promising Renewable Energy Sources (RES) that can be used to produce electric energy through Photovoltaic (PV) process. The Solar Photovoltaic (SPV) systems which directly supply power to the grid are becoming more popular. A power electronic converter which converts DC power from the PV array to AC power at required voltage and frequency levels is known as Inverter. Generally different Pulse Width Modulation (PWM) techniques have been implemented for grid connected 3-phase Voltage Source Inverter (VSI) system. This paper describes few types of PWM techniques and mathematical model of LC filter circuit is given using state space analysis. Sine-PWM technique is proposed for 3-phase VSI and implemented using the state space model of the LC filter circuit. The simulation is performed in MATLAB/Simulink platform. Simulation results are presented for the inverter and load side to demonstrate the satisfactory performance of the sine-PWM technique.

KEYWORDS:

1.      Pulse width modulation
2.      Solar photovoltaic
3.      Voltage source inverter

SOFTWARE: MATLAB/SIMULINK

BLOCK DIAGRAM:


Fig. 1. General Block Diagram of Grid Connected SPV system

EXPECTED SIMULATION RESULTS:


Fig. 2. Carrier wave (Vtri) and Modulating wave (Vsin)



 Fig. 3. Inverter Output line to line Voltages (ViAB,ViBC,ViCA)


Fig. 4. Inverter Output Currents (iiA,iiB,iiC)


Fig. 5. Load line to line voltages (VLAB, VLBC, VLCA)


Fig. 6. Load Phase Currents (iLA,iLB,iLC)



Fig. 7. Inverter output line voltage, Inverter output current, Load line
voltage, Load phase currents
CONCLUSION:
Increasing demand on energy efficiency and power quality issues, grid connected solar PV systems is taking a good place. In this paper SPWM and SVPWM techniques have been discussed for 3-phase grid connected VSI. The LC filter circuit is used in the proposed system. This filter circuit is mathematically modeled by using state space analysis and complete state space equation is obtained. The SPWM technique is implemented and simulated on 3 phases VSI using state space model of the LC filter circuit for grid connected solar PV system. Various simulation results are analyzed and presented on the inverter and load side of the proposed system in order to demonstrate the satisfactory performance of sine-PWM technique for grid connected solar PV system.

 REFERENCES:
[1] J.Y. Lee, and Y.Y. Sun, “A New SPWM Inverter with Minimum Filter Requirement,” International Journal of Electronics, Vol. 64, No. 5, pp. 815-826, 1988.
[2] K. Zhou and D. Wang, “Relationship Between Space-Vector Modulation and Three- Phase Carrier-Based PWM: A Comprehensive Analysis,” IEEE Transactions on Industrial Electronics, Vol. 49, No. 1, pp. 186- 196, February 2002.
[3] A.W. Leedy, and R.M. Nelms, “Harmonic Analysis of a Space Vector PWM Inverter using the Method of Multiple Pulses,” IEEE Transactions on Industrial Electronics, Vol. 4, pp. 1182-1187, July 2006.
[4] A.M. Khambadkone, and J. Holtz, “Current Control in Over-modulation Range for Space Vector Modulation based Vector Controlled Induction Motor Drives,” IEEE Industrial Electronics Society, Vol.2, pp. 1134- 1339, 2000.

[5] E. Hendawi, F. Khater, and A. Shaltout, “Analysis, Simulation and Implementation of Space Vector Pulse Width Modulation Inverter,” International Conference on Application of Electrical Engineering, pp. 124-131, 2010.

Wednesday, 1 February 2017

Indirect Vector Control of Induction Motor Using Sliding-Mode Controller


ABSTRACT:
The paper presents a sliding-mode speed control system for an indirect vector controlled induction motor drive for high performance. The analysis, design and simulation of the sliding-mode controller for indirect vector control induction motor are carried out. The proposed sliding-mode controller is compared with PI controller with no load and various load condition. The result demonstrates the robustness and effectiveness of the proposed sliding-mode control for high performance of induction motor drive system.

KEYWORDS:
1.      Indirect vector control
2.      Sliding mode control
3.      PI controller
4.      Induction motor
5.      Speed control

SOFTWARE: MATLAB/SIMULINK

 BLOCK DIAGRAM:

Figure 1: Indirect vector controlled induction motor drive
                                                                                                                                                       
EXPECTED SIMULATION RESULTS:



Figure 2: Speed response of PI controller at no load



Figure 3:Speed response of Sliding-mode controller at no load



Figure 4: Speed response of PI controller at load


Figure 5: Speed response of Sliding- mode controller at load


Figure 6:X-Y plot of Rotor flux of PI controller



Figure 7: x-v plot of Rotor flux of Sliding-mode controller


CONCLUSION:

In this paper sliding-mode controller for the control of an indirect vector-controlled induction motor was described. The drive system was simulated with sliding-mode controller and PI controller and their performance was compared. Here simulation results shows that the designed sliding-mode controller realises a good dynamic behaviour of the motor with a rapid settling time, no overshoot and has better performance than PI controller. Sliding-mode control has more robust during change in load condition.
.
 REFERENCES:

[1] B.K Bose "Modern power electronics and ac drives "Prentice-Hall OJ India, New Delhi, 2008.
[2] M.Masiala;B.Vafakhah,;A.Knght,;J.Salmon,;"Performa nce of PI and fuzzy logic speed control of field-oriented induction motor drive," CCECE , jul. 2007, pp. 397-400.
[3] F.Barrero;A.Gonzalez;A.Torralba,E.Galvan,;L.G.Franqu elo; "Speed control of induction motors using a novel Fuzzy-sliding mode structure,"IEEE Transaction on Fuzzy system, vol. 10, no.3, pp. 375-383, Jun 2002.
[4] H.F.Ho,K.W.E.Cheng, "position control of induction motor using indirect adaptive fuzzy sliding mode control," P ESA, , Sep. 2009, pp. 1-5.
[5] RKumar,R.A.Gupta,S.V.Bhangale, "indirect vector controlled induction motor drive with fuzzy logic based intelligent controller," IETECH Journals of Electrical Analysis, vol. 2, no. 4, pp. 211-216, 2008.