asokatechnologies@gmail.com 09347143789/09949240245

Search This Blog

Friday 30 November 2018

Permanent Magnet Synchronous Generator Based Wind Energy and DG Hybrid System



ABSTRACT:
This paper investigates the use of permanent magnet synchronous generators (PMSGs) for a wind energy conversion system (WECS) and a diesel engine driven generator (DG) set of a standalone hybrid system with a battery energy storage system (BESS). For voltage control at the point of common coupling (PCC) and balanced supply at terminals of DG set, a single phase D-Q theory based control algorithm is applied for the switching of voltage source converter (VSC) of BESS and the maximum power point tracking (MPPT) is achieved for WECS with an incremental conductance technique for the switching of a dc-dc boost converter. Simulation results of developed model of proposed standalone hybrid system, which is developed in MATLAB demonstrate performance of both the controllers and power quality improvement of the hybrid system.
KEYWORDS:
1.      WECS
2.      Diesel Generator
3.      Single-Phase D-Q theory
4.      Power Quality
5.      MPPT

SOFTWARE: MATLAB/SIMULINK

 SCHEMATIC DIAGRAM:



Fig. 1 Schematic diagram of Wind-Diesel hybrid configuration
 EXPECTED SIMULATION RESULTS:




Fig. 2 (a) Characteristics of the system with constant wind speed under
varying loads.


Fig. 3 (b) Estimation of supply currents and voltages using control algorithm



Fig.4 (c) dynamic Performance of controller of hybrid system under varying
linear loads at 10 m/s wind speed


Fig. 5(a) Characteristics of the system with constant wind speed under varying
loads.

Fig. 6(b) Estimation of supply currents and voltages using control algorithm

Fig.7(c) dynamic Performance of controller of hybrid system under varying
nonlinear loads at 10 m/s wind speed.


Fig. 8 waveforms and harmonic spectra (a) Phase ‘a’ supply voltage of at
PCC (b) Phase ‘a’ supply current under nonlinear unbalanced loads.


Fig. 9 Controllers’ performance under wind speed reduction (11 m/s-8 m/s)


Fig. 10  Controllers’ performance under rise in wind speed (8 m/s-11 m/s)

 CONCLUSION:

A 3-φ standalone wind-diesel hybrid system using PMSG along with BESS has been simulated in MATLAB using Simpower system tool boxes. Various components have been designed for the hybrid system and controller’s satisfactory performance has been depicted using 1-φ-D-Q theory with SOGI filters for various loads under dynamic conditions while maintaining constant voltage at PCC and balanced source currents of diesel generator and also for harmonics suppression as per guidelines of IEEE-519-1992 standard. A mechanical sensor less approach has been used for achieving MPPT through incremental conductance technique.

REFERENCES:
 [1] Bin Wu, Y. Lang, N. Zargari, and Samir Kouro, Handbook of Power Conversion and Control of Wind Energy Systems, John Wiley and Sons, Hoboken, New Jersey, 2011.
[2] B. Singh, and R. Niwas, “Power quality improvements in diesel engine driven induction generator system using SRF theory,” in Proc. of IEEE  Fifth Power India Conference, 2012, pp.1,5, 19-22 Dec. 2012.
[3] B. Singh, and J. Solanki, “Load Compensation for Diesel Generator Based Isolated Generation System Employing DSTATCOM,” in Proc. of IEEE International Conference on Power Electronics, Drives and Energy Systems, 2006, PEDES '06, pp.1-6, 12-15 Dec. 2006.
[4] S. Sharma, and B. Singh, “An autonomous wind energy conversion system with permanent magnet synchronous generator,” in Proc. Of Inter. Conf. on Energy, Automation, and Signal (ICEAS), 2011, pp.1-6, 28-30 Dec. 2011.
[5] P.K. Goel, B. Singh, S.S. Murthy, and N. Kishore, “Autonomous hybrid system using SCIG for hydro power generation and variable speed PMSG for wind power generation,” in Proc. of Inter. Conf. on Power Electronics and Drive Systems, PEDS’ 2009, pp.55-60, 2-5 Nov. 2009.

Tuesday 27 November 2018

Permanent Magnet Synchronous Generator-Based Standalone Wind Energy Supply System




ABSTRACT

In this paper, a novel algorithm, based on dc link voltage, is proposed for effective energy management of a standalone permanent magnet synchronous generator (PMSG)-based variable speed wind energy conversion system consisting of battery, fuel cell, and dump load (i.e., electrolyzer). Moreover, by maintaining the dc link voltage at its reference value, the output ac voltage of the inverter can be kept constant irrespective of variations in the wind speed and load. An effective control technique for the inverter, based on the pulse width modulation (PWM) scheme, has been developed to make the line voltages at the point of common coupling (PCC) balanced when the load is unbalanced. Similarly, a proper control of battery current through dc–dc converter has been carried out to reduce the electrical torque pulsation of the PMSG under an unbalanced load scenario. Based on extensive simulation results using MATLAB/SIMULINK, it has been established that the performance of the controllers both in transient as well as in steady state is quite satisfactory and I can also maintain maximum power point tracking.
KEYWORDS
1.      DC-side active filter
2.      Permanent magnet synchronous generator (PMSG)
3.      Unbalanced load compensation
4.      Variable speed wind turbine
5.      Voltage control
SOFTWARE: MATLAB/SIMULINK

BLOCK DIAGRAM


Fig. 1. PMSG-based standalone wind turbine with energy storage and dump load.

 EXPECTED SIMULATION RESULTS




Fig. 2. Response of mechanical torque for change in wind velocity.



Fig. 3. (a) Load current; (b) wind speed.




Fig. 4. DC link voltage.



Fig. 5. RMS output voltage (PCC voltage).


Fig. 6. Instantaneous output voltage at s.



Fig. 7. Instantaneous output line current.


Fig. 8. Powers.


Fig.9. Powers.


Fig. 10. DC link voltage.



Fig. 11. Powers.


Fig. 12. DC link voltage.




Fig. 13. Response of controllers.



Fig. 14. Three phase currents for unbalanced load.





Fig. 15. Electrical torque of PMSG with and without dc–dc converter controller.


Fig. 16. Instantaneous line voltages at PCC for unbalanced load.




Fig. 17. (a) RMS value of line voltages at PCC after compensation; (b) modulation indexes.



Fig. 18. Instantaneous line voltages at PCC after compensation.

CONCLUSION
Control strategies to regulate voltage of a standalone variable speed wind turbine with a PMSG, battery, fuel cell, and electrolyzer (acts as dump load) are presented in this paper. By maintaining dc link voltage at its reference value and controlling modulation indices of the PWM inverter, the voltage of inverter output is maintained constant at their rated values. From the simulation results, it is seen that the controller can maintain the load voltage quite well in spite of variations in wind speed and load.An algorithm is developed to achieve intelligent energy management among the wind generator, battery, fuel cell, and electrolyzer. The effect of unbalanced load on the generator is analyzed and the dc–dc converter control scheme is proposed to reduce its effect on the electrical torque of the generator. The dc–dc converter controller not only helps in maintaining the dc voltage constant but also acts as a dc-side active filter and reduces the oscillations in the generator torque which occur due to unbalanced load. PWM inverter control is incorporated to make the line voltage at PCC balanced under an unbalanced load scenario. Inverter control also helps in reducing PCC voltage excursion arising due to slow dynamics of aqua elctrolyzer when power goes to it. The total harmonic distortion (THD) in voltages at PCC is about 5% which depicts the good quality of voltage generated at the customer end. The simulation results demonstrate that the performance of the controllers is satisfactory under steady state as well as dynamic conditions and under balanced as well as unbalanced load conditions.


REFERENCES

[1] S. Müller, M. Deicke, and W. De DonckerRik, “Doubly fed induction generator system for wind turbines,” IEEE Ind. Appl. Mag., vol. 8, no. 3, pp. 26–33, May/Jun. 2002.
[2] H. Polinder, F. F. A. van der Pijl, G. J. de Vilder, and P. J. Tavner, “Comparison of direct-drive and geared generator concepts for wind turbines,” IEEE Trans. Energy Convers., vol. 21, no. 3, pp. 725–733, Sep. 2006.
[3] T. F. Chan and L. L. Lai, “Permanent-magnet machines for distributed generation: A review,” in Proc. 2007 IEEE Power Engineering Annual Meeting, pp. 1–6.
[4] M. Fatu, L. Tutelea, I. Boldea, and R. Teodorescu, “Novel motion sensorless control of standalone permanent magnet synchronous generator (PMSG): Harmonics and negative sequence voltage compensation under nonlinear load,” in Proc. 2007 Eur. Conf. Power Electronics and Applications, Aalborg, Denmark, Sep. 2–5, 2007.
[5] M. E. Haque, K. M. Muttaqi, and M. Negnevitsky, “Control of a standalone variable speed wind turbine with a permanent magnet synchronous generator,” in Proc. IEEE Power and Energy Society General Meeting, Jul. 2008, pp. 20–24.

Saturday 24 November 2018

Grid Connected Wind- Photovoltaic hybrid System



 ABSTRACT

This paper presents a modeling and control strategies of a grid connected Wind-Photovoltaic hybrid system. This proposed system consists of two renewable energy sources in order to increase the system efficiency. The Maximum Power Point Tracking (MPPT) algorithm is applied to the PV system and the wind system to obtain the maximum power for any given external weather conditions. The generator side converter is controlled by the Field Oriented Control (FOC). This approach is used to control independently the flux and the torque by applying the d- and q-components of the current motor. The utility grid side converter is controlled by the Voltage Oriented Control (VOC) strategy which is adopted to adjust the DC-link at the desired voltage. The simulation results using PSIM software environment prove the good performance of these used techniques to generate sinusoidal current waveforms. This current is synchronized with the grid voltage. Moreover, the DC bus voltage is perfectly constant because only the active power is injected into the grid. Simulations are carried out to validate the effectiveness of the proposed system methods.
KEYWORDS
1.      Converter
2.      FOC
3.      Grid
4.      hybrid system
5.      MPPT control
6.      photovoltaic system
7.      SCIG
8.      VOC
9.      Wind turbine
SOFTWARE: MATLAB/SIMULINK
BLOCK DIAGRAM


Fig. l.The proposed PV -wind hybrid system

 EXPECTED SIMULATION RESULTS


Fig. 2 Solar irradiance changes


Fig. 3 The variation of PY arrays current

Fig. 4 The PY arrays voltage

Fig. 5 The PY arrays power and reference

Fig. 6 Duty cycle

Fig. 7 Wind speed profile

Fig. 8 Electrical angular speed of the SCIG and its reference

Fig. 9 The active power injected into the grid

Fig. 10 The Reactive power injected into the grid

Fig. 11 The waveforms of the current


Fig. 12 The three phase current and voltage waveforms

Fig. 13. DC link voltage.
CONCLUSION
In this paper, Wind-Photo voltaic hybrid system control has been investigated. An MPPT method has been studied. It has been simulated with different solar irradiation and wind speed environments in order to maximize the output power of the proposed system . Two control techniques have been employed to improve the hybrid system usefulness . The controlled rectifier connected to the squirrel-cage induction generator (SCIG) has been controlled by the Field Oriented Control (FOC) to reach the optimal rotational speed, The grid-side inverter has been controlled by the Voltage Oriented Control (VOC) method to keep the dc-link voltage at the desired value. The hybrid system simulation has been implemented in PSIM software and its performances were proved when the solar irradiance change or the wind speed occurs.
REFERENCES

[1] Liyuan Chen, Yun Liu "Scheduling Strategy of Hybrid Wind Photovoltaic- Hydro Power Generation System" International Conference on Sustainable Power Generation and Supply (SUPERGEN 2012), Sept. 2012.
[2] Akhilesh P. Pati!, Rambabu A. Vatti and Anuja S. Morankar," Simulation of Wind Solar Hybrid Systems Using PSIM " International Journal of Emerging Trends in Electrical and Electronics (lJETEE), Vol. 10, Issue. 3, April-2014.
[3] Rabeh Abbassi, Manel Hammami, Souad Chebbi. "Improvement of the integration of a grid connected wind-photovoltaic hybrid system" Electrical Engineering and Software Applications (lCEESA), International Conference , 2013
[4] Harini M., Ramaprabha R. and Mathur B. L. "Modeling of grid connected hybrid windlPV generation system using matlab, Vol. 7,no. 9, September 2012.
[5] Nabil A. Ahmed "On-Grid Hybrid Wind/Photovoltaic/Fuel Cell Energy System" Conference on Power & Energy ( IPEC), December 2012.