Simulation and Analysis of Perturb and Observe MPPT Algorithm for PV Array Using ĊUK Converter

Simulation and Analysis of Perturb and Observe MPPT
Algorithm for PV Array Using ĊUK Converter


ABSTRACT:

This paper presents the comparative analysis between constant duty cycle and Perturb & Observe (P&O) algorithm for extracting the power from Photovoltaic Array (PVA). Because of nonlinear characteristics of PV cell, the maximum power can be extract under particular voltage condition. Therefore, Maximum Power Point Tracking (MPPT) algorithms are used in PVA to maximize the output power. In this paper the MPPT algorithm is implemented using Ćuk converter. The dynamics of PVA is simulated at different solar irradiance and cell temperature. The P&O MPPT technique is a direct control method enables ease to implement and less complexity.

KEYWORDS

1.      Photovoltaic Array (PVA)
2.       MPPT
3.       ĆUK Converter

SOFTWARE: MATLAB/SIMULINK

BLOCK DIAGRAM:





Fig. 1: Block Diagram of MPPT Using PI Controller


Fig. 2: Block Diagram of Direct Duty Cycle (δ) Control MPPT

EXPECTED SIMULATION RESULTS:



Fig. 3: MATLAB/SIMULINK Model of PVCC for δ =0.6




Fig. 4: Output Power Curve of the PV Module and Ćuk Converter for Constant δ = 0.6 and Different β.



Fig. 5: Output Power Curve of the PV Module and Ćuk Converter for Constant δ = 0.6 and Different T




Fig. 6: MATLAB/SIMULINK Model of PVCC Using P & O Algorithm





Fig. 7: Output Power Curve of the PV Module and Ćuk Converter for Different β and P&O MPPT



Fig. 8: Output Power Curve of the PV Module and Ćuk Converter for Different T and P & O MPPT.

CONCLUSION:

In this paper, P&O and constant duty cycle algorithm of MPPT is implemented using ĆUK converter. The model is simulated with MATLAB/SIMULINK. It is shown that PV system output power increases with rise in solar irradiance and fall in cell temperature. Therefore, solar cell performance better in winter season than summer. The P&O gives the optimum duty cycle as compare to Constant duty cycle control, to extract the maximum power from PV system.

REFERENCES:

[1] Ali Chermitti, Omar Boukli-Hacene and Samir Mouhadjer (2012) “Design of a Library of Components for Autonomous Photovoltaic System under Matlab/Simulink”, International Journal of Computer Applications (0975 – 8887), Volume 53– No.14.
[2] Ankur Bhattacharjee (2012) “Design and Comparative Study of Three Photovoltaic Battery Charge Control Algorithms in MATLAB/SIMULINK Environment”, International Journal of Advanced Computer Research (ISSN (print): 2249-7277 ISSN (online): 2277-7970), Volume-2 Number-3 Issue-5.
[3] Athimulam Kalirasu and Subharensu Sekar Dash (2010) “Simulation of Closed Loop Controlled Boost Converter for Solar Installation,” SERBIAN JOURNAL OF ELECTRICAL ENGINEERING, Vol. 7, No. 1.
[4] Azadeh Safari and Saad Mekhilef (2011) “Simulation and Hardware Implementation of Incremental Conductance MPPT with Direct Control Method Using Cuk Converter”, IEEE Transaction on Industrial Electronics, Vol.58, no.4.

[5] E. Durán, M.B. Ferrera, J.M. Andújar, M.S. Mesa (2011) “I-V and P-V Curves Measuring System for PV Modules based on DC-DC Converters and Portable Graphical Environment” IEEE, 978-1-4244.

Sunday 28 December 2014

Transformer less Inverter with Virtual DC Bus Concept for Cost-Effective Grid-Connected PV Power Systems

Transformer less Inverter with Virtual DC Bus Concept for Cost-Effective Grid-Connected PV Power Systems

ABSTRACT:

In order to eliminate the common-mode (CM) leakage current in the transformer less photovoltaic (PV) systems, the concept of the virtual dc bus is proposed in this paper. By connecting the grid neutral line directly to the negative pole of the dc bus, the stray capacitance between the PV panels and the ground is bypassed. As a result, the CM ground leakage current can be suppressed completely. Meanwhile, the virtual dc bus is created to provide the negative voltage level for the negative ac grid current generation. Consequently, the required dc bus voltage is still the same as that of the full-bridge inverter. Based on this concept, a novel transformer less inverter topology is derived, in which the virtual dc bus is realized with the switched capacitor technology. It consists of only five power switches, two capacitors, and a single filter inductor. Therefore, the power electronics cost can be curtailed. This advanced topology can be modulated with the uni polar sinusoidal pulse width modulation (SPWM) and the double frequency SPWM to reduce the output current ripple. As a result, a smaller filter inductor can be used to reduce the size and magnetic losses. The advantageous circuit performances of the proposed transformer less topology are analyzed in detail, with the results verified by a 500-W prototype.


KEYWORDS

1.      Common mode (CM) current
2.       Photovoltaic (PV) system
3.       Switched capacitor
4.       Transformer less inverter
5.       Unipolar sinusoidal pulse width modulation (SPWM)
6.       Virtual dc bus.

SOFTWARE: MATLAB/SIMULINK

BLOCK DIAGRAM:

Fig.1. Proposed topology.

 EXPECTED SIMULATION RESULTS:





Fig.2. Output current and grid voltage.



Fig.3. Current harmonics distribution.


                                             

Fig.4. Simulation waveform for reactive power generation





Fig.5. Current stress on S3 .




Fig. 6. Enlarged figure for current stress on S3

.                                     


 Fig. 7. CM current of H5 circuit.


Fig. 8. Current stress under different capacitor ratios for the proposed circuit: (a) C1 /C2 = 1/2; (b) C1 /C2 = 2/1.
             
CONCLUSION:

The concept of the virtual dc bus is proposed to solve the CM current problem for the transformer less grid-connected PV inverter. By connecting the negative pole of the dc bus directly to the grid neutral line, the voltage on the stray PV capacitor is clamped to zero. This eliminates the CM current completely. Meanwhile, a virtual dc bus is created to provide the negative voltage level. The required dc voltage is only half of the half bridge solution, while the performance in eliminating the CM current is better than the full-bridge-based inverters. Based on this idea, a novel inverter topology is proposed with the virtual dc bus concept by adopting the switched capacitor technology. It consists of only five power switches and a single filter inductor. The proposed topology is especially suitable for the small-power single-phase applications, where the output current is relatively small so that the extra current stress caused by the switched capacitor does not cause serious reliability problem for the power devices and capacitors. With excellent performance in eliminating the CM current, the virtual dc bus concept provides a promising solution for the transformer less grid-connected PV inverters.

REFERENCES:

[1] J. P. Benner and L. Kazmerski, “Photovoltaics gaining greater visibility,” IEEE Spectr., vol. 36, no. 9, pp. 34–42, Sep. 1999.
[2] Z. Zhao, M. Xu, Q. Chen, J.-S. Lai, and Y. Cho, “Derivation of boost-buck converter based high-efficiency robust PV inverter,” in Proc. IEEE Energy Convers. Cong. Expos., Sep. 12–16, 2010, pp. 1479–1484.
[3] R.W. Erickson and A. P. Rogers, “A microinverter for building-integrated photovoltaics,” in Proc. 24th Annu. IEEE Appl. Power Electron. Conf. Expos., Feb. 15–19, 2009, pp. 911–917.
[4] S. B. Kjaer, J. K. Pedersen, and F. Blaabjerg, “A review of single-phase grid-connected inverters for photovoltaic modules,” IEEE Trans. Ind. Appl., vol. 41, no. 5, pp. 1292–1306, Sep./Oct. 2005.

[5] E. Koutroulis and F. Blaabjerg, “Design optimization of grid-connected PV inverters,” in Proc. 26th Annu. IEEE Appl. Power Electron. Conf. Expos., Mar. 6–11, 2011, pp. 691–698.

Dynamic Simulation of a Three-Phase Induction Motor Using Matlab Simulink

Dynamic Simulation of a Three-Phase Induction Motor Using Matlab Simulink


ABSTRACT:

 The theory of reference frames has been effectively used as an efficient approach to analyze the performance of the induction electrical machines. This paper presents a step by step Simulink implementation of an induction machine using dq0 axis transformations of the stator and rotor variables in the arbitrary reference frame. For this purpose, the relevant equations are stated at the beginning, and then a generalized model of a three-phase induction motor is developed and implemented in an easy to follow way. The obtained simulated results provide clear evidence that the reference frame theory is indeed an attractive algorithm to demonstrate the steady-state behavior of the induction machines.

 SOFTWARE: MATLAB/SIMULINK

 BLOCK DIAGRAM:

Figure 1 the 3-phase induction motor Matlab/Simulink model

EXPECTED SIMULATION RESULTS:



Figure 2 Torque speed characteristics for the 3 hp induction motor

Figure 3 Machine variables during free acceleration of a 3-hp induction motor

Figure 4 Torque speed characteristics for the 2250 hp induction motor

Figure  5 Machine variables during free acceleration  of a 2250-hp induction motor  
            
CONCLUSION:

In this paper, an implementation and dynamic modeling of a three-phase induction motor using Matlab/Simulink are presented in a step-by-step manner. The model was tested by two different ratings of a small and large induction motors. The two simulated machines have given a satisfactory response in terms of the torque and speed characteristics. Also, the model was evaluated by Matlab m-file coding program. Both methods have given the same results for the same specifications of the three phase induction motors used in this simulation. This concludes that the Matlab/Simulink is a reliable and sophisticated way to analyze and predict the behavior of induction motors using the theory of reference frames.

REFERENCES:

[1] P. C. Krause, O. Wasynczuk, S. D. Sudhoff “Analysis of Electric Machinery and Drive Systems”, IEEE Press, A John Wiley & Sons, Inc. Publication Second Edition, 2002.
[2] P.C. Krause and C. H. Thomas, “Simulation of Symmetrical Induction Machinery”, IEEE Transaction on Power Apparatus and Systems, Vol. 84, November 1965, pp. 1038-1053.
[3] P. C. Krause, “Analysis of Electric Machinery”, McGraw-Hill Book Company, 1986.
[3] D. C. White and H. H. Woodson, “Electromechanical Energy Conversion”, John Wiley and Sons, New York, 1959.
[4] M. L. de Aguiar, M. M. Cad, “The concept of complex transfer functions applied to the modeling of induction motors”, Power Engineering Society Winter Meeting, 2000, pp. 387–391.

[5] S. Wade, M. W. Dunnigan, B. W. Williams, “Modeling and simulation of induction machine vector control with rotor resistance identification”, IEEE Transactions on Power Electronics, vol. 12, No. 3, May 1997, pp. 495–506.

Wednesday 24 December 2014

Implementation of Adaptive Filter in Distribution Static Compensator

Implementation of Adaptive Filter in Distribution Static Compensator

ABSTRACT:

This paper presents an implementation of an adaptive filter in a three-phase distribution static compensator (DSTATCOM) used for compensation of linear/nonlinear loads in a three-phase distorted voltage ac mains. The proposed filter, which is based on adaptive synchronous extraction, is used for extraction of fundamental active- and reactive-power components of load currents in estimating the reference supply currents. This control algorithm is implemented on a developed DSTATCOM for reactive-power compensation, harmonics elimination, load balancing, and voltage regulation under linear and nonlinear loads. The performance of DSTATCOM is observed satisfactory under unbalanced time-varying loads.

KEYWORDS

1.      Adaptive filter (AF)
2.      distribution static compensator (DSTATCOM)
3.       harmonics
4.       load balancing
5.       sinusoidal tracking algorithm
6.       voltage-source converter (VSC)

SOFTWARE: MATLAB/SIMULINK

 BLOCK DIAGRAM:

Fig.1. Schematic of three-leg DSTATCOM.

EXPECTED SIMULATION RESULTS:



                                                            (a)

                                                              (b)

Fig. 2. (a), (b), and (c) Various intermediate signals of the control algorithm at load injection. (a) Ch. 1 and 2: 200 V/div; Ch. 3 and 4: 20 A/div; Time axis: 50 ms/div. (b) Ch. 1, 2, 3, and 4: 20 A/div; Time axis: 20 ms/div. (c) Ch. 1, 2,3, and 4: 20 A/div; Time axis: 20 ms/div.

 Fig. 3. Steady-state performance of DSTATCOM at linear lagging PF load in PFC mode. (a) Ps. (b) PL. (c) Pc. (d) vab, isa. (e) vbc, isb. (f) vca, isc.


 Fig. 4. Steady-state performance of DSTATCOM at nonlinear loads in PFC mode. (a) vab, isa. (b) vbc, isb. (c) vca, isc. (d) Harmonic spectrum of isa. (e) vab, iLa. (f) Harmonic spectrum of iLa.   


Fig. 5. Dynamic performance of DSTATCOM at unbalanced linear loads. (a) vab, isa, isb, isc. (b) vab, iLa, iLb, iLc. (c) vdc, isa, iCa, iLa.


Fig. 6. Dynamic performance of DSTATCOM at unbalanced nonlinear loads. (a) vab, isa, isb, isc. (b) vab, iLa, iLb, iLc. (c) vdc, isa, iCa, iLa
.


Fig. 7. Steady-state performance of DSTATCOM at linear lagging PF load in ZVR mode. (a) Ps. (b) PL. (c) Pc. (d) vab, isa. (e) vbc, isb. (f) vca, isc.

Fig. 8. Steady-state performance of DSTATCOM at nonlinear load in ZVR mode. (a) vab, isa. (b) vbc, isb. (c) vca, isc. (d) Harmonic spectrum of isa. (e) Harmonic spectrum of iLa. (f) iCa. (g) Ps. (h) PL.

 
Fig. 9. Variation of Vt, isa, and iLa with vdc under unbalanced linear loads.

CONCLUSION:

A DSTATCOM has been implemented for a three-phase distribution system. An AF has been used for control of DSTATCOM. This AF has been found simple and easy to implement, and its performance has been observed satisfactory with nonsinusoidal and distorted voltages of ac mains under load variation. The performance of DSTATCOM with its AF has been demonstrated for harmonics elimination, reactivepower compensation, and load balancing with self-supporting dc link in PFC and ZVR modes. The dc-link voltage of the DSTATCOM has been also regulated to a desired value under time-varying load conditions.

REFERENCES:

[1] E. F. Fuchs and M. A. S. Mausoum, Power Quality in Power Systems and Electrical Machines. London, U.K.: Elsevier, 2008.
[2] H. Akagi, E. H. Watanabe, and M. Aredes, Instantaneous Power Theory and Applications to Power Conditioning. Hoboken, NJ, USA: Wiley, 2007.
[3] A. Emadi, A. Nasiri, and S. B. Bekiarov, Uninterruptible Power Supplies and Active Filters. Boca Raton, FL, USA: CRC Press, 2005.
[4] J. Jacobs, D. Detjen, C. U. Karipidis, and R. W. De Doncker, “Rapid prototyping tools for power electronic systems: Demonstration with shunt active power filters,” IEEE Trans. Power Electron., vol. 19, no. 2, pp. 500– 507, Mar. 2004.

[5] A. Ghosh and G. Ledwich, Power Quality Enhancement Using Custom Power Devices. New Delhi, India: Springer Int. Edition, 2009.