Offshore Wind Farm Power Control Using HVdc Link Control de puissance d’un parc éolien en mer utilisant la liaison CCHT


ABSTRACT:
KEYWORDS:
4.       PQ-bus

SOFTWARE: MATLAB/SIMULINK

BLOCK DIAGRAM:



Fig. 1. Proposed configuration of wind turbines connection.


EXPECTED SIMULATION RESULTS:




Fig. 2. (a) Wind speed variations (m/s). (b) Turbine rotational speed (rad/s).
(c) Turbine efficiency.




Fig. 3. HVdc link voltage.



Fig. 4. Wind farm output power.
CONCLUSION:
In this paper, the configuration and control methods have been proposed for the offshore wind turbines, connected to the onshore grid. This method is capable to control and smooth the wind farm output power, injected to the onshore grid. The proposed system can mitigate the fluctuations of wind farm output power, even during wind speed variations. In other words, the wind farm can operate such as a PQ-bus. Moreover, two strategies (fixed power and MPPT) have been analyzed and compared with each other. Finally, the proposed method is compared with other similar works to smooth the output power of the wind farm. The main result is that the proposed method can smooth the output power better than the TSR, PAC, and OTC methods. But it is a bit weaker than the KEC method in power smoothing issue. Moreover, using this method, the wind farm is able to cooperate in frequency control of the onshore grid by controlling the desired active power, to improve the power system operation, which is the future work of the authors.
REFERENCES:
[1] J. O. Dabiri, “Potential order-of-magnitude enhancement of wind farm power density via counter-rotating vertical-axis wind turbine arrays,” J. Renew. Sustain. Energy, vol. 3, no. 4, p. 043104, 2011.
[2] J. Hua, “A floating platform of concrete for offshore wind turbine,” J. Renew. Sustain. Energy, vol. 3, no. 6, p. 063103, 2011.
[3] A. Urtasun, P. Sanchis, I. S. Martín, J. López, and L. Marroyo, “Modeling of small wind turbines based on PMSG with diode bridge for sensorless maximum power tracking,” Renew. Energy, vol. 55, pp. 138–149, Jul. 2012.
[4] (2007). Global Wind and Energy Council, Market Forecast 2010- 2014. [Online]. Available: http://www.gwec.net/fileadmin/documents/ Publications/GlobalWind2007report/market/forecast%2020102014

[5] M. Kesraoui, N. Korichi, and A. Belkadi, “Maximum power point tracker of wind energy conversion system,” Renew. Energy, vol. 4, no. 10, pp. 2655–2662, 2011.

Modeling and Control of Multi-Terminal HVDC with Offshore Wind Farm Integration and DC Chopper Based Protection Strategies


ABSTRACT:
KEYWORDS:
2.      DFIG
3.      DC chopper
4.      Faults
 SOFTWARE: MATLAB/SIMULINK

BLOCK DIAGRAM:
                                                         Fig. 1 Topology of the proposed multi-terminal VSC-HVDC system.

EXPECTED SIMULATION RESULTS:



Fig. 2 Simulation results of MT-HVDC during normal operation: (a) active power of wind farm, (b) dc voltage, and (c) ac rms current.


Fig. 3 Simulation results of 6 DFIG units during normal operation: (a) active power, (b) reactive power, (c) ac rms voltage, and (d) back-to-back dc-link voltage of DFIG unit.


Fig. 4 Simulation results of MT-HVDC during dc pole-to-pole fault with and without full bridge dc chopper protection: (a) dc voltage, and (b) dc current.

Fig. 5 Simulation results of MT-HVDC during three-phase ac ground fault at inverter side with and without half bridge dc chopper protection: (a) ac rms voltage at inverter side, (b) dc voltage overshoot without protection measures, and (c) dc voltage with protection measures.
CONCLUSION:
This paper investigates a multi-terminal VSC-HVDC system, which integrates two DFIG wind farms to the ac grid. The control strategies of both WFVSC and GSVSC stations are discussed in detail, and two approaches employing both full bridge and half bridge dc choppers are extended and displayed. Simulation studies are carried out in normal, dc pole-to-pole and ac ground fault operations, and the result verifies the effectiveness of the proposed MT-HVDC system in both the performance of wind power delivery and the protection measures for various fault conditions. Specifically, the dc voltage drop and dc current overshoot are eliminated during dc fault with full bridge dc choppers, while only a 8% voltage overshoot is observed with the implementation of half bridge dc choppers in case of three-phase ac ground fault.
REFERENCES:
 [1] S. G. Hernandez, E. M. Goytia and O. A. Lara, “Analysis of wide area integration of dispersed wind farms using multiple VSC-HVDC links,” in Proc. of EPE, Sevilla, pp. 17-26, 2008.
[2] S. Towito, M. Berman, G. Yehuda and R. Rabinvici, “Distribution generation case study: electric wind farm doubly fed induction generators”, in Proc. Convention of Electrical and Electronics Engineering(CEEE), Israel, pp. 393-397, Nov. 2006.
[3] N. Flourentzou, V. G. Agelidis, and G. D. Demetriades, “VSC-based HVDC power transmission systems: an overview,” IEEE Trans. Power Electron., vol. 24, no. 3, pp. 592-602, Mar. 2009.
[4] L. Xu, L. Yao, and C. Sasse, “Grid integration of large DFIG-based wind farms ssing VSC transmission,” IEEE Trans. Power Syst., vol. 22, no. 3, pp.976-984, Aug. 2007.

[5] L. Weimers, “HVDC Light: A new technology for a better environment”, IEEE Power Eng. Review, vol. 18, no. 8, pp.19-20, Aug. 1998.

Inertial Response of an Offshore Wind Power Plant with HVDC-VSC


 ABSTRACT:

KEYWORDS:
2.       Inertial response
3.       Offshore wind turbine

SOFTWARE: MATLAB/SIMULINK

 BLOCK DIAGRAM:


Fig. 1. Test system schematic
EXPECTED SIMULATION RESULTS:


Fig. 2. ΔT order applied to the controller of the DFIG


Fig. 3. DFIG rotating speed, 150 MW


Fig. 4. DFIG electromagnetic torque, 150 MW


Fig. 5. HVDC link voltage , 150 MW


Fig. 6. HVDC link current, 150 MW


Fig. 7. Real and reactive power (rectifier side), 150 MW


Fig. 8. Real and reactive power (inverter side), 150 MW


Fig. 9. DFIG rotating speed, 180 MW


Fig. 10. DFIG electromagnetic torque, 180 MW


Fig. 11. HVDC link voltage , 180 MW


Fig. 12. HVDC link current, 180 MW


Fig. 13. Real and reactive power (rectifier side), 180 MW


Fig. 14. Real and reactive power (inverter side), 180 MW


Fig. 15. DFIG rotating speed, 200 MW, 12 m/s


Fig. 16. DFIG electromagnetic torque, 200 MW, 12 m/s



Fig. 17. HVDC link voltage , 200 MW, 12 m/s


Fig. 18. HVDC link current, 200 MW, 12 m/s

CONCLUSION:
Detailed time domain simulations were conducted in order to analyze the transients present on the inertial response of an offshore WPP delivering power through an HVDC-VSC link. Several results from transient behavior are presented, these results show that an offshore WPP connected to the grid via an HVDC-VSC link is able to deliver inertial response if it is requested.
These results are important as the WPP importance for the power system is growing and its performance during contingencies must be asured.
REFERENCES:
[1] A. Bodin, “HVDC Light—A Preferable Power Transmission System for Renewable Energies.” Proceedings of the 2011 Third International Youth Conference on Energetics; July 7–9, 2011, Leiria, Portugal
[2] M. de Prada Gil, O. Gomis-Bellmunt, A. Sumper, and J. Bergas-Jané, “Analysis of a Multi-Turbine Offshore Wind Farm Connected to a Single Large Power Converter Operated with Variable Frequency.” Energy (36: 5), May 2011; pp. 3272–3281
[3] Feltes, C., and Erlich, I. “Variable Frequency Operation of DFIG-Based Wind Farms Connected to the Grid Through VSC-HVDC Link.” IEEE Power Engineering Society General Meeting, June 24–28, 2007, Tampa, Florida.
[4] N. Miller, K. Clark, M. Cardinal, and R. Delmerico, "Grid-friendly wind plants controls: GE Wind CONTROL—Functionality and field tests," presented at European Wind Energy Conf., Brussels, Belgium, 2008.

[5] N. W. Miller, K. Clark, and M. Shao, “Impact of frequency responsive wind plant controls on grid performance,” presented at 9th International Workshop on Large-Scale Integration of Wind Power, Quebec, Canada, Oct. 18–19, 2010.

Monday 14 August 2017

Harmonics Reduction And Power Quality Improvement By Using DPFC



ABSTRACT:
The DPFC is derived from the unified power-flow controller (UPFC). The DPFC can be considered as a UPFC with an eliminated common dc link. The active power exchange between the shunt and series converters which is through the common dc link in the UPFC is now through the transmission lines at the third-harmonic frequency. The DPFC employs the distributed concept, in which the common dc-link between the shunt and series converters are eliminated and three-phase series converter is divided to several single-phase series distributed converters through the line. According to the growth of electricity demand and the increased number of non-linear loads in power grids harmonics, voltage sag and swell are the major power quality problems. DPFC is used to mitigate the voltage deviation and improve power quality. Simulations are carried out in MATLAB/Simulink environment. The presented simulation results validate the DPFC ability to improve the power quality.
KEYWORDS:
1.      Load flow control
2.      FACTS
3.      Power Quality
4.       Harmonics
5.      Sag and Swell Mitigation
6.       Distributed Power Flow Controller
7.       Y–Δ transformer

SOFTWARE: MATLAB/SIMULINK

BLOCK DIAGRAM:


Fig. 1. DPFC configuration

EXPECTED SIMULATION RESULTS:



Fig 2. three phase voltage sag waveform without DPFC


Fig. 3 three phase voltage sag waveform with DPFC



Fig.4 3-ϕ load current swell waveform without DPFC


Fig.5 Mitigation of 3-ϕ load current swell with DPFC
              


Fig.6 Total harmonic distortion of load voltage without DPFC

.


Fig.7 Total harmonic distortion of load voltage with DPFC

CONCLUSION:
This paper has presented a new concept called DPFC. The DPFC emerges from the UPFC and inherits the control capability of the UPFC, which is the simultaneous adjustment of the line impedance, the transmission angle, and the bus voltage magnitude. The common dc link between the shunt and series converters, which is used for exchanging active power in the UPFC, is eliminated. This power is now transmitted through the transmission line at the third-harmonic frequency. The series converter of the DPFC employs the DFACTS concept, which uses multiple small single-phase converters instead of one large-size converter. The reliability of the DPFC is greatly increased because of the redundancy of the series converters. The total cost of the DPFC is also much lower than the UPFC, because no high-voltage isolation is required at the series-converter part and the rating of the components of is low. To improve power quality in the power transmission system, the harmonics due to nonlinear loads, voltage sag and swell are mitigated. To simulate the dynamic performance, a three-phase fault is considered near the load. It is shown that the DPFC gives an acceptable performance in power quality improvement and power flow control.

REFERENCES:
[1] S.Masoud Barakati Arash Khoshkbar sadigh and Mokhtarpour.Voltage Sag and Swell Compensation with DVR Based on Asymmetrical Cascade Multicell Converter North American Power Symposium (NAPS),pp.1-7,2011.
[2] Zhihui Yuan, Sjoerd W.H de Haan, Braham Frreira and Dalibor Cevoric “A FACTS Device: Distributed Power Flow Controller (DPFC)” IEEE Transaction on Power Electronics, vol.25, no.10, October 2010.
[3] Zhihui Yuan, Sjoerd W.H de Haan and Braham Frreira “DPFC control during shunt converter failure” IEEE Transaction on Power Electronics 2009.
[4] M. D. Deepak, E. B. William, S. S. Robert, K. Bill, W. G. Randal, T. B. Dale, R. I. Michael, and S. G. Ian, “A distributed static series compensator system for realizing active power flow control on existing power lines,” IEEE Trans. Power Del., vol. 22, no. 1, pp. 642–649, Jan. 2007.

[5] D. Divan and H. Johal, “Distributed facts—A new concept for realizing grid power flow control,” in Proc. IEEE 36th Power Electron. Spec. Conf. (PESC), 2005, pp. 8–14.