Power Quality Improvement of PMSG Based DG Set Feeding Three-Phase Loads



ABSTRACT:

This paper presents power quality improvement of PMSG (Permanent Magnet Synchronous Generator) based DG (Diesel Generator) set feeding three-phase loads using STATCOM (Static Compensator). A 3-leg VSC (Voltage Source Converter) with a capacitor on the DC link is used as STATCOM. The reference source currents for the system are estimated using an Adaline based control algorithm. A PWM (Pulse Width Modulation) current controller is using for generation of gating pulses of IGBTs (Insulated Gate Bipolar Transistors) of three leg VSC of the STATCOM. The STATCOM is able to provide voltage control, harmonics elimination, power factor improvement, load balancing and load compensation. The performance of the system is experimentally tested on various types of loads under steady state and dynamic conditions. A 3-phase induction motor with variable frequency drive is used as a prototype of diesel engine with the speed regulation. Therefore, the DG set is run at constant speed so that the frequency of supply remains constant irrespective of loading condition.
KEYWORDS:

1.      STATCOM
2.      VSC
3.      IGBTs
4.      PMSG
5.      PWM
6.      DG Set
7.      Power Quality

SOFTWARE: MATLAB/SIMULINK

CIRCUIT DIAGRAM:

Fig. 1 Configuration of PMSG based DG set feeding three phase loads.

EXPECTED SIMULATION RESULTS:



Fig. 2. Dynamic performance at linear loads (a) vsab, isa,isb and isc ,(b) vsab, iLa,iLb and iLc (c) Vdc, isa,iLa and iCa
CONCLUSION:
The STATCOM has improved the power quality of the PMSG based DG set in terms voltage control, harmonics elimination and load balancing. Under linear loads, there has been negligible voltage variation (From 219.1 V to 220.9 V) and in case of nonlinear load, the voltage increases to 221 V. Thus, the STATCOM has been found capable to maintain the terminal voltage of DG set within ± 0.5% (220 ±1 V) under different linear and nonlinear loads.
Under nonlinear loads, the load current of DG set is a quasi square with a THD of 24.4 %. The STATCOM has been found capable to eliminate these harmonics and thus the THD of source currents has been limited to 3.9 % and the THD of terminal voltage has been observed of the order of 1.8%. Therefore, the THDs of source voltage and currents have been maintained well within limits of IEEE-519 standard under nonlinear load.
It has also been found that the STATCOM maintains balanced source currents when the load is highly unbalanced due to removal of load from phase ‘c’. The load balancing has  also been achieved by proposed system with reduced stress on the winding of the generator.
The proposed system is a constant speed DG set so there is no provision of frequency control in the control algorithm.
However, the speed control mechanism of prototype of the diesel engine is able to maintain the frequency of the supply almost at 50 Hz with small variation of ±0.2 %.
Therefore, the proposed PMSG based DG set along with STATCOM can be used for feeding linear and nonlinear balanced and unbalanced loads. The proposed PMSG based DG set has also inherent advantages of low maintenance, high efficiency and rugged construction over a conventional wound field synchronous generator based DG set.


REFERENCES:

[1] Xibo Yuan; Fei Wang; Boroyevich, D.; Yongdong Li; Burgos, R., "DC-link Voltage Control of a Full Power Converter for Wind Generator Operating in Weak-Grid Systems," IEEE Transactions on Power Electronics, vol.24, no.9, pp.2178-2192, Sept. 2009.
[2] Li Shuhui, T.A. Haskew, R. P. Swatloski and W. Gathings, "Optimal and Direct-Current Vector Control of Direct-Driven PMSG Wind Turbines," IEEE Trans. Power Electronics, vol.27, no.5, pp.2325-2337, May 2012.
[3] M. Singh and A. Chandra, "Application of Adaptive Network-Based Fuzzy Inference System for Sensorless Control of PMSG-Based Wind Turbine With Nonlinear-Load-Compensation Capabilities," IEEE Trans. Power Electronics, vol.26, no.1, pp.165-175, Jan. 2011.
[4] A. Rajaei, M. Mohamadian and A. Yazdian Varjani, "Vienna-Rectifier-Based Direct Torque Control of PMSG for Wind Energy Application," IEEE Trans. Industrial Elect., vol.60, no.7, pp.2919-2929, July 2013.
[5] Mihai Comanescu, A. Keyhani and Dai Min, "Design and analysis of 42-V permanent-magnet generator for automotive applications," IEEE Trans. Energy Conversion, vol.18, no.1, pp.107-112, Mar 2003.