Autonomous Power Control and Management Between Standalone DC Microgrids



ABSTRACT:
Renewable integrated DC Microgrids (DCMGs) are gaining popularity by feeding remote locations in qualitative and quantitative manner. Reliability of autonomous DC microgrids (ADCMG) depend on battery capacity and size due to stochastic behavior of renewables. Over charging and discharging scenarios compel the microgrid into insecure zone. Increasing the storage capacity is not an economical solution because of additional maintenance and capital cost. Thus interconnecting neighbor microgrids increases virtual storing and discharging capacity when excess power and deficit scenario arises respectively in any of the DCMG. Control strategy plays vital role in regulating the power within and between microgrids. Power control and management technique is developed based on bus signaling method to govern sources, storages and loads to achieve effective coordination and energy management between microgrids. Proposed scheme is simple and reliable since bus voltages are utilized in shifting the modes without having dedicated communication lines. Proposed scheme is validated through real time simulation of two autonomous DC grids in real time digital simulator (RTDS) and its results are validated by hardware experimentation.
KEYWORDS:
1.      Autonomous DC Microgrid
2.      Bus signaling method
3.      Power control and management scheme
4.      Renewable sources
5.      Real time simulation
SOFTWARE: MATLAB/SIMULINK

BLOCK DIAGRAM:


Fig. 1. System architecture for interconnection of two ADCMGs.



EXPECTED SIMULATION RESULTS




Fig. 2. Operating zones of ADCMG1: (a) Bus voltage, (b) Irradiation, (c) PV
output power, (d) Battery terminal voltage, (e) Battery output power, and (f) Load power.


Fig. 3. Operating zones of ADCMG2: (a) Bus voltage, (b) Irradiation, (c) PV
output power, (d) Battery terminal voltage, (e) Battery output power, and (f)
Load power.




Fig. 4. Operation of BDC using PCMS: (a) ADCMG1 voltage, (b) ADCMG2
voltage, (c) Power exported from ADCMG1, (d) Power exported from
ADCMG2, (e) Powers within ADCMG1, and (f) Powers within ADCMG2.

CONCLUSION:
A PCMS is developed based on bus signaling technique for inter DC grid power flow in case of ADCMGs to increase the system reliability and efficient utilization of resources. Two practical DC grid voltages (380V, 48V) are considered for evaluating the performance of developed scheme in simulation. PCMS is explored under normal and extreme scenarios including the over and under loading conditions of ADCMGs, further more with over charging and discharging of battery. It can be observed from above analysis that proposed PCMS is stable, efficient and effective in realizing communication independent control even under dynamic power variations during the power exchange. This statement is also justified with experimental results obtained through prototype model developed in the laboratory with reduced voltage of ADCMG1. Proposed system provides isolation and also enhances system reliability. Application potential of system suits low and medium voltage customers like domestic consumers, data centers, telecommunication systems, etc. in isolated locations where utility connection is not present or feasible.
REFERENCES:
[1] T. Dragicevi, X. Lu, J. C. Vasquez, and J. M.Guerrero, “DC Microgrids – Part II: A Review of Power Architectures, Applications and Standardization Issues,” IEEE Trans. Power Electron., vol. 31, no. 5, pp. 3528–3549, May. 2016.
[2] Q. Yang, L. Jiang, H. Zhao, and H. Zeng, “Autonomous Voltage Regulation and Current Sharing in Islanded Multi-inverter DC Microgrid,” IEEE Trans. Smart Grid, vol. PP, no. 99, pp. 1–1, 2017.
[3] J. Torreglosa, P. Garcia, L. Fernandez, and F. Jurado, “Predictive Control for the Energy Management of a Fuel Cell-Battery-Supercapacitor Tramway,” IEEE Trans. Ind. Informat., vol. 10, no. 1, pp. 276-285, Feb. 2013.
[4] L. Herrera, W. Zhang, and J. Wang, “Stability Analysis and Controller Design of DC Microgrids with Constant Power Loads,” IEEE Trans. Smart Grid, vol. 8, no. 2, pp. 881–888, March. 2017.
[5] D. E. Olivares, A. Mehrizi-sani, A. H. Etemadi, C. A. Cañizares, R. Iravani, M. Kazerani, A. H. Hajimiragha, O. Gomis-bellmunt, M. Saeedifard, R. Palma-behnke, G. A. Jiménez-estévez, and N. D. Hatziargyriou, “Trends in Microgrid Control,” IEEE Trans. Smart Grid, vol. 5, no. 4, pp. 1905–1919, July. 2014.

An Improved DC-Link Voltage Control Strategy for Grid Connected Converters



 ABSTRACT:
This paper presents a robust control strategy to improve dc-link voltage control performances for Grid connected Converters (GcCs). The proposed control strategy is based on an adaptive PI controller and is aimed to ensure fast transient response, low dc-link voltage fluctuations, low grid current THD and good disturbance rejection after sudden changes of the active power drawn by the GcC. The proportional and integral gains of the considered adaptive PI controller are self-tuned so that they are well suited with regard to the operating point of the controlled system and/or its state. Several simulation and experimental results are presented to confirm and validate the effectiveness and feasibility of the proposed dc-link voltage control strategy.

KEYWORDS:
1.      DC-link voltage control
2.      adaptive PI controller
3.      Grid connected Converters


SOFTWARE: MATLAB/SIMULINK

 BLOCK DIAGRAM:



 Fig. 1. Commonly used control structure for Grid-connected Converters


 EXPECTED SIMULATION RESULTS



Fig. 2. Simulation results (ξ=0.7, Vdc init=100V, Vdc
*=150, i=0 at t=0s and i=Imax at t=0.5s) (a) Comparison between standard PI control and adaptive PI control  (b) waveform of the selected ωn value for the adaptive PI controller



CONCLUSION:
This paper presented an improved dc-link voltage controller based on an adaptive PI controller with an anti-windup process. The proportional and integral gains of the proposed PI controller are self-tuned so that the following constraints are satisfied: 1) no overshoot after step jumps of the dc-link voltage reference input; 2) fast dynamic response after step jumps of the dc-link voltage reference; 3) fast dynamic response after step jump of the input current i and 4) low grid current THD value during steady state operation. The considered control was experimentally tested on a prototyping platform. The obtained experimental results are quite similar to simulation results and show the effectiveness and reliability of the adopted control strategy.
REFERENCES:
[1] D. Casadei, M. Mengoni, G. Serra, A. Tani, and L. Zarri, “A control scheme with energy saving and dc-link overvoltage rejection for induction motor drives of electric vehicles,” IEEE Trans. Ind. Appl.,vol. 46, no. 4, pp. 1436–1446, Jul./Aug. 2010.
[2] Li, F., Zou, Y.P., Wang, C.Z., Chen, W., Zhang, Y.C., Zhang, J. “Research on AC Electronic Load Based on back to back Single phase PWM Rectifiers,” Applied Power Electronics Conference and Exposition, 2008. APEC 2008. Twenty-Third Annual IEEE. 2008, pp.630-634. 2008.
[3] M. Karimi-Ghartimani, S.A. Khajehoddin, P. Jain, A. Bakhshai, “A systematic approach to dc-bus control design in single phase grid connected renewable converters,” IEEE Trans. Power Electron, vol. 28, no. 7, pp. 3158–3166, July. 2013.
[4] X. Yuan, F. Wang, D. Boroyevich, Y. Li, and R. Burgos, “Dc-link voltage control of a full power converter for wind generator operating in weak-grid systems,” IEEE Trans. Power Electron., vol. 24, no. 9, pp. 2178–2192, Sep. 2009.
[5] C.-S. Lam, W.-H. Choi, M.-C. Wong, and Y.-D. Han, “Adaptive dc link voltage-controlled hybrid active power filters for reactive power compensation,” IEEE Trans. Power Electron., vol. 27, no. 4, pp. 1758– 1772, Apr. 2012.



An f-P/Q Droop Control in Cascaded-Type Microgrid



ABSTRACT:
In cascaded-type microgrid, the synchronization and power balance of distributed generators become two new issues that needs to be addressed urgently. To that end, an f-P/Q droop control is proposed in this letter, and its stability is analyzed as well. This proposed droop control is capable to achieve power balance under both resistive-inductive an resistive-capacitive loads autonomously. Compared with the inverse power factor droop control, an obvious advantage consists in extending the scope of application. Finally, the feasibility of the proposed method is verified by simulation results.

KEYWORDS:
1.      Cascaded-type microgrid
2.      Droop control
3.      Power balance

SOFTWARE: MATLAB/SIMULINK

BLOCK DIAGRAM:


Fig. 1. Structure of islanded cascaded-type microgrid.
CONTROL  SYSTEM:



Fig. 2. The local control diagram of the i-th DG.
EXPECTED SIMULATION RESULTS





Fig.3. Simulation results of case I. (a) Active power. (b) Reactive power





Fig. 4. Simulation results of case II. (a) Active power. (b) Reactive power.

 CONCLUSION:
A bridge modular switched-capacitor-based multilevel inverter with optimized UFD-SPWM control method is proposed in the paper. The switched-capacitor-based stage can obtain high conversion efficiency and multiple voltage levels. Meanwhile, it functions as an active energy buffer, enhancing the power decoupling ability and conducing to cut the total size of the twice-line energy buffering capacitance. Furthermore, voltage multi-level in DC-link reduces the switching loss of inversion stage because turn-off voltage stress of switches changes with phase of output voltage rather than always suffers from one relatively high DC voltage. Most importantly, the control method of UFD-SPWM, doubling equivalent witching frequency, is employed in the inversion stage for a high quality output waveform with reduced harmonic. In addition, the optimized voltage level phase maximizes the fundamental component in output voltage pulses to reduce harmonic backflow as possible. Hence, the comprehensive system efficiency has been promoted and up to peak value of 97.6%. Finally, two conversion stages are controlled independently for promoting reliability and decreasing complexity. In future work, detailed loss discussion, including theoretic calculation and validation of loss breakdown, will be presented.

REFERENCES:
[1] M. Jun, "A new selective loop bias mapping phase disposition PWM with dynamic voltage balance capability for modular multilevel converter," IEEE Trans. Ind. Electron., vol. 61, no. 2, pp. 798-807, Feb. 2014.
[2] N. Mehdi, and G. Moschopoulos, "A novel single-stage multilevel type full-bridge converter," IEEE Trans. Ind. Electron., vol. 60, no. 1, pp. 31-42, Jan. 2013.
[3] E. Ehsan and N. B. Mariun, "Experimental results of 47-level switchladder multilevel inverter," IEEE Trans. Ind. Electron., vol. 60, no. 11, pp. 4960-4967, Nov. 2013.
[4] J. Lai, “Power conditioning circuit topologies,” IEEE Trans. Ind. Electron., vol. 3, no. 2, pp. 24-34, Jun. 2009.
[5] L. He, C. Cheng, “Flying-Capacitor-Clamped Five-Level Inverter Based on Switched-Capacitor Topology,” IEEE Trans. Ind. Electron., vol. 63, no.12, pp. 7814-7822, Sep. 2016.





Thursday, 1 November 2018

A Buck & Boost based Grid Connected PV Inverter Maximizing Power Yield from Two PV Arrays in Mismatched Environmental Conditions



ABSTRACT:
A single phase grid connected transformerless photo voltaic (PV) inverter which can operate either in buck or in boost mode, and can extract maximum power simultaneously from two serially connected subarrays while each of the subarray is facing different environmental conditions, is presented in this paper. As the inverter can operate in buck as well as in boost mode depending on the requirement, the constraint on the minimum number of serially connected solar PV modules that is required to form a subarray is greatly reduced. As a result power yield from each of the subarray increases when they are exposed to different environmental conditions. The topological configuration of the inverter and its control strategy are designed so that the high frequency components are not present in the common mode voltage thereby restricting the magnitude of the leakage current associated with the PV arrays within the specified limit. Further, high operating efficiency is achieved throughout its operating range. A detailed analysis of the system leading to the development of its mathematical model is carried out. The viability of the scheme is confirmed by performing detailed simulation studies. A 1.5 kW laboratory prototype is developed, and detailed experimental studies are carried out to corroborate the validity of the scheme.
KEYWORDS:
1.      Grid connection
2.      Single phase
3.      Transformerless
4.      Buck & Boost based PV inverter
5.      Maximum power point
6.      Mismatched environmental condition
7.      Series connected module
SOFTWARE: MATLAB/SIMULINK

CIRCUIT DIAGRAM:
Fig. 1. Dual Buck & Boost based Inverter (DBBI)

EXPECTED SIMULATION RESULTS



Fig. 2. Simulated waveform: Variation in (a) ppv1 and ppv2, (b) vpv1 and
vpv2, (c) ipv1 and ipv2 during entire range of operation

Fig.3. Simulated waveform: vg and ig and their magnified views

Fig. 4. Simulated waveform: iL1 and iL2 and their magnified views


Fig. 5. Simulated waveform: vco1 and vco2 and their magnified views
CONCLUSION:

A single phase grid connected transformerless buck and boost based PV inverter which can operate two subarrays at their respective MPP was proposed in this paper. The attractive features of this inverter were i) effect of mismatched environmental conditions on the PV array could be dealt with A single phase grid connected  transformerless buck and boost based PV inverter which can operate two subarrays at their respective MPP was proposed in this paper. The attractive features of this inverter were i) effect of mismatched environmental conditions on the PV array could be dealt with in an effective way, ii) operating efficiency achieved, _euro = 97.02% was high, iii) decoupled control of component converters was possible, iv) simple MPPT algorithm was employed to ensure MPP operation for the component converters, v) leakage current associated with the PV arrays was within the limit mentioned in VDE 0126-1-1. Mathematical analysis of the proposed inverter leading to the development of its small signal model was carried out. The criterion to select the values of the output filter components was presented. The scheme was validated by carrying out detailed simulation studies and subsequently the viability of the scheme was ascertained by carrying out thorough experimental studies on a 1.5 kW prototype of the inverter fabricated for the purpose.
REFERENCES:
[1] T. Shimizu, O. Hashimoto, and G. Kimura, “A novel high-performance utility-interactive photovoltaic inverter system,” IEEE Trans. Power Electron., vol. 18, no. 2, pp. 704-711, Mar. 2003.
[2] S. V. Araujo, P. Zacharias, and R. Mallwitz, “Highly efficient singlephase transformerless inverters for grid-connected photovoltaic systems,” IEEE Trans. Ind. Electron., vol. 57, no. 9, pp. 3118-3128, Sep. 2010.
[3] B. Ji, J. Wang, and J. Zhao, “High-efficiency single-phase transformerless PV H6 inverter with hybrid modulation method,” IEEE Trans. Ind.Electron., vol. 60, no. 5, pp. 2104-2115, May 2013.
[4] R. Gonzalez, E. Gubia, J. Lopez, and L. Marroyo, “Transformerless single phase multilevel-based photovoltaic inverter,” IEEE Trans. Ind. Electron., vol. 55, no. 7, pp. 2694-2702, Jul. 2008.
[5] H. Xiao and S. Xie, “Transformerless split-inductor neutral point clamped three-level PV grid-connected inverter,” IEEE Trans. Power Electron., vol. 27, no. 4, pp. 1799-1808, Apr. 2012.

A Grid Connected Single Phase Transformerless Inverter Controlling Two Solar PV Array Operating under Different Atmospheric Conditions



ABSTRACT:
A grid connected single phase transformerless inverter which can operate two serially connected solar photo voltaic (PV) subarrays at their respective maximum power points while each one of them is exposed to different atmospheric conditions is proposed in this paper. As two subarrays are connected in series, the number of serially connected modules within a subarray is reduced to half. Reduction in the number of serially connected PV modules within a subarray leads to an overall improvement in the magnitude of power that can be abstracted from a subarray while the modules of the subarray are exposed to varied atmospheric conditions. The topological structure of the inverter ensures that the common mode voltage does not contain high frequency components, thereby reducing the magnitude of leakage current involved with the solar panels well within the acceptable limit. An in depth analysis of the scheme along with the derivation of its small signal model has been carried out. Detailed simulation studies are performed to verify its effectiveness. A 1 kW laboratory prototype of the scheme has been fabricated. Detailed experimental validations have been carried out utilizing the prototype to confirm the viability of the proposed scheme.
KEYWORDS:
1.      Grid connected single phase transformerless PV inverter
2.      Maximum power extraction
3.      Mismatched operating condition
4.      Serially connected PV subarrays

SOFTWARE: MATLAB/SIMULINK

 PROPOSED CIRCUIT DIAGRAM:



Fig. 1. Combined Half Bridge Inverter with AC Bypass (CHBIAB)

 EXPECTED SIMULATION RESULTS:



Fig.2. Simulated performance: (a) Power output from PV1 and PV2, (b) Voltage output of PV1 and PV2, (c) Output current of PV1 and PV2

Fig. 3. Simulated performance: Grid current and voltage along with their
magnified versions 

Fig. 4. Simulated performance: Output capacitor voltages along with their magnified versions

CONCLUSION:
A grid connected single phase transformerless inverter which can extract maximum power from two subarrays during  mismatched operating condition is presented in this paper. Salient features of the proposed inverter are as follows: i) number of series connected modules is less thereby reducing the effect of shading, ii) two subarrays can be operated at MPP simultaneously, thus it is well suited for PV subarrays operating under mismatched operating condition, iii) decoupled control structure is employed to control the two component half bridges of the inverter, iv) _euro of 96% is achieved which is the highest compared to the topologies dealing with solar PVs experiencing mismatched operating conditions, v) the scheme is realized through single stage of power conversion leading to a considerable reduction in size, weight and volume, vi) simple MPPT algorithm is employed thereby reducing the computational burden of the digital signal processor involved, vii) PV leakage current is limited within the limit specified in the standard, VDE 0126-1-1. The operating principle of the proposed scheme is explained in detail by exploring all the equivalent topological stages. Subsequently the mathematical analysis of the scheme has been carried out and the small signal model of the scheme has been derived. The philosophy of control is described in detail and the configuration of the controller is derived. The design guidelines for selecting the filter components of the inverter are presented. Detailed simulation and experimental studies are carried out to confirm the viability of the proposed scheme.

REFERENCES:
[1] T. Kerekes, R. Teodorescu, P. Rodriguez, G. Vazquez, and E. Aldabas, “A new high-efficiency single-phase transformerless PV inverter topology,” IEEE Trans. Industrial Electronics, vol. 58, no. 1, pp. 184-191, Jan. 2011.
[2] S. V. Araujo, P. Zacharias, and R. Mallwitz, “Highly efficient single phase transformerless inverters for grid-connected photovoltaic systems,” IEEE Trans. Industrial Electronics, vol. 57, no. 9, pp. 3118- 3128, Sep. 2010.
[3] G. M. Masters, Renewable and efficient electric power systems, New Jersey: John Wiley & Sons Inc, 2004, ISBN: 0-471-28060-7.
[4] T. Shimizu, O. Hashimoto, and G. Kimura, “A novel high-performance utility-interactive photovoltaic inverter system,” IEEE Trans. Power Electronics, vol. 18, no. 2, pp. 704-711, Mar. 2003.
[5] T. Shimizu, M. Hirakata, T. Kamezawa, and H. Watanabe, “Generation control circuit for photovoltaic modules,” IEEE Trans. Power Electronics vol. 16, no. 3, pp. 293-300, May 2001.