asokatechnologies@gmail.com 09347143789/09949240245

Search This Blog

Thursday, 19 March 2020

Development of High-Performance Grid-Connected Wind Energy Conversion System for Optimum Utilization of Variable Speed Wind Turbines


ABSTRACT:
This paper presents an improvement technique for the power quality of the electrical part of a wind generation system with a self-excited induction generator (SEIG) which aims to optimize the utilization of wind power injected into weak grids. To realize this goal, an uncontrolled rectifier-digitally controlled inverter system is proposed. The advantage of the proposed system is its simplicity due to fewer controlled switches which leads to less control complexity. It also provides full control of active and reactive power injected into the grid using a voltage source inverter (VSI) as a dynamic volt ampere reactive (VAR) compensator. A voltage oriented control (VOC) scheme is presented in order to control the energy to be injected into the grid. In an attempt to minimize the harmonics in the inverter current and voltage and to avoid poor power quality of the wind energy conversion system (WECS), an filter is inserted between VOC VSI and the grid. The proposed technique is implemented by a digital signal processor (DSP TMS320F240) to verify the validity of the proposed model and show its practical superiority in renewable energy applications.
KEYWORDS:
1.      Grid connected systems
2.      Self-excited induction generator (SEIG)
3.      Voltage oriented control (VOC)
4.      Voltage source inverter (VSI)
5.      Wind energy conversion systems (WECSs)

SOFTWARE: MATLAB/SIMULINK

BLOCK DIAGRAM:





Fig. 1. Proposed SEIG-based WECS with VOC VSI.

 EXPERIMENTAL RESULTS:




Fig. 2. Line voltage of theVSI in frame (400 V/div–5ms). (a) Simulation.
(b) Experiment.



Fig. 3. Phase voltage of the VSI in frame (400 V/div–5 ms). (a) Simulation.
(b) Experiment.



Fig. 4. Grid phase voltage (50 V/div–10 ms) and injected current
(1 A/div–10 ms). (a) Simulation. (b) Experiment.



Fig. 5. Inverter phase voltage to be connected to the grid with only filter
(50 V/div–10 ms). (a) Simulation. (b) Experiment.



Fig. 6. Grid voltage (50 V/div–25 ms) and injected current (1 A/div–25 ms)
under step change in the reactive power injected into grid. (a) Simulation.
(b) Experiment.




Fig. 7. VSI response with filter for the grid and capacitor voltage
(100 V/div–10 ms) with the injected line current (5 A/div–10 ms). (a) Simulation.
(b) Experiment.



Fig. 8. Harmonic spectrum analysis with filter. (a) Injected current harmonic
content. (b) Filter capacitor voltage harmonic content.

CONCLUSION:
In this paper, the SEIG-based WECS dynamic model has been derived. The VOC grid connected VSI has been investigated for high performance control operation. The test results showed how the control scheme succeeded in injecting the wind power as active or reactive power in order to compensate the weak grid power state. An filter is inserted between VOC VSI and grid to obtain a clean voltage and current waveform with negligible harmonic content and improve the power quality. Also, this technique achieved unity power factor grid operation (average above 0.975), very fast transient response within a fraction of a second (0.4 s) under different possible conditions (wind speed variation and load variation), and high efficiency due to a reduced number of components (average above 90%) has been achieved. Besides the improvement in the converter efficiency, reduced mechanical and electrical stresses in the generator are expected, which improves the overall system performance. The experimental results obtained from a prototype rated at 250 W showed that the current and voltage THD (2.67%, 0.12%), respectively, for the proposed WECS with filter is less than 5% limit imposed by IEEE-519 standard. All results obtained confirm the effectiveness of the proposed system feasible for small-scale WECSs connected to weak grids.
REFERENCES:
[1] V. Kumar, R. R. Joshi, and R. C. Bansal, “Optimal control of matrix-converter-based WECS for performance enhancement and efficiency optimization,” IEEE Trans. Energy Convers., vol. 24, no. 1, pp. 264–272, Mar. 2009.
[2] Y. Zhou, P. Bauer, J. A. Ferreira, and J. Pierik, “Operation of grid connected DFIG under unbalanced grid voltage,” IEEE Trans. Energy Convers., vol. 24, no. 1, pp. 240–246, Mar. 2009.
[3] S. M. Dehghan, M.Mohamadian, and A. Y. Varjani, “A new variable speed wind energy conversion system using permanent-magnet synchronous generator and z-source inverter,” IEEE Trans Energy Convers., vol. 24, no. 3, pp. 714–724, Sep. 2009.
[4] K. Tan and S. Islam, “Optimum control strategies for grid-connected wind energy conversion system without mechanical sensors,” WSEAS Trans. Syst. Control, vol. 3, no. 7, pp. 644–653, Jul. 2008, 1991-8763.
[5] B. C. Rabelo, W. Hofmann, J. L. da Silva, R. G. de Oliveira, and S. R. Silva, “Reactive power control design in doubly fed induction generators for wind turbines,” IEEE Trans. Ind. Elect., vol. 56, no. 10, pp. 4154–4162, Oct. 2009.

Sunday, 8 March 2020

Intelligent Energy Control Center for Distributed Generators Using Multi-Agent System



ABSTRACT:
This paper presents the modeling of intelligent energy control center (ECC) controlling distributed generators (DGs) using multi-agent system. Multi-agent system has been proposed to provide intelligent energy control and management in grids because of their benefits of extensibility, autonomy, reduced maintenance, etc. The multi-agent system constituting the smart grid and agents such as user agent, control agent, database agent, distributed energy resources (DER) agent work in collaboration to perform assigned tasks. The wind power generator connected with local load, the solar power connected with local load and the ECC controlled by fuzzy logic controller (FLC) are simulated in MATLAB/SIMULINK. The DER model is created in client and ECC is created in server. Communication between the server and the client is established using transmission control protocol/internet protocol (TCP/IP). The results indicate that the controlling of DER agent can be achieved both from server and client.
KEYWORDS:
1.      Distributed energy resources (DER) and transmission control protocol/internet protocol (TCP/IP)
2.      Distributed generators (DGs)
3.      Energy control center (ECC)
4.      Fuzzy logic controller (FLC)

SOFTWARE: MATLAB/SIMULINK

BLOCK DIAGRAM:




Fig. 1. Block diagram of power system interconnected with wind and solar
power generation scheme.

EXPERIMENTAL RESULTS:




Fig. 2. Voltage waveform of wind and solar power – circuit breaker (CB-1) closed after 0.1 s and circuit breaker (CB-2) closed after 0.3 s to interconnect solar power to wind.






Fig. 3. Voltage waveform of wind and solar power circuit breaker (CB-1) closed after 0.1 s and circuit breaker (CB-2) closed after 0.3 s to interconnect  solar power to wind observed up to 0.6 s.

CONCLUSION:
The simulation model of ECC, controlling the solar power generation and wind power generation interconnected with grid using multi-agent system is described in this paper. The voltage of wind and solar power are stored in a excel sheet as a database agent. Intelligent controller FLC controls the switch provided in the solar panel to add/remove depending upon the voltage requirements. This excel sheet acting as a monitoring tool to access the simulation results, provides the visualization of the grid. The results prove that the multi-agent component controls the Distributed Energy Resources.

REFERENCES:
[1] T. Nagata and H. Sasaki, “A multi-agent approach to power system restoration,” IEEE Trans. Power Syst., vol. 17, no. 2, pp. 457–462, May 2002.
[2] T. A. Dimeas and N. D. Hatziargyriou, “Operation of a multi-agent system for microgrid control,” IEEE Trans. Power Syst., vol. 20, no. 3,  pp. 1447–1455, Aug. 2005.
[3] S. G. Ankaliki, “Energy control center functions for power system,” Int. J. Math. Sci., Technol., Humanities, vol. 2, no. 1, pp. 205–212, 2012.
[4] R. L. Krutz, Securing SCADA Systems. New York, NY, USA: Wiley, 2006.
[5] O. Castillo and P. melin, Studies in Fuzziness and Soft Computing Type2 Fuzzy Logic : Theory and Applications. NewYork,NY,USA: Springer-Verlag, 2008.

Saturday, 7 March 2020

Simulation and Analysis of MPPT Algorithms for Solar PV based Charging Station



ABSTRACT:
Maximum Power Point Tracking (MPPT) algorithms is conferred in this paper used in photovoltaic (PV) systems for changing temperature and irradiance conditions. The MPPT control is always combined with a DC-DC power converter to produce maximal power under differing metrological conditions. The boost converter is used along with the Maximum Power Point Tracking control system. Perturb and Observe (P&O) and Incremental Conductance algorithm (INC) are the two widely used algorithms for drawing maximal power from the photovoltaic source. Direct duty ratio control technique is used for both the algorithms. The system is modeled using MATLAB Simulink software. The simulation result of 50W PV module produced by the two algorithms are analysed and a comparative study is presented.

KEYWORDS:
1.      Maximum power point tracking (MPPT)
2.      MATLAB SIMULINK
3.      Photovoltaic (PV)
4.      Perturb and Observe (P&O)
5.      Incremental conductance (INC)
6.      Duty ratio (D)

SOFTWARE: MATLAB/SIMULINK

BLOCK DIAGRAM:


Fig.1. Block diagram of MPPT control

 EXPERIMENTAL RESULTS:



Fig.2. Non-linear P-V and I-V curves for 1000 W/m2 at 25áµ’C


                                                         
                                                          Fig.3. I-V and P-V curves for different irradiance values at 25áµ’C



Fig.4. Waveforms at irradiance values from 400 W/m2 – 800 W/m2 for a
step time of 0.4 seconds at 25áµ’C



Fig.5. Waveforms at irradiance values from 800W/m2 – 1000 W/m2 for a
step time of 0.4 seconds at 25áµ’C



Fig.6.Waveforms at irradiance values from 400 W/m2- 800 W/m2 for a
step time of 0.4 seconds at 25áµ’C


Fig.7. Waveforms at irradiance values from 800 W/m2 -1000 W/m2 for a
step time of 0.4 seconds at 25áµ’C



CONCLUSION:
A mathematical model of a 50W photovoltaic (PV) panel modeled with MPPT control algorithms is discussed in this paper. The Perturb and Observe algorithm, and Incremental conductance algorithm are explained and simulated using the MATLAB Simulink. Here the MPPT control is achieved by direct duty ratio control of the boost converter which is linked to the load for its maximum efficiency under varying temperature and irradiance values of solar PV panel. The Perturb and Observe (P&O) method is simple to implement. It has slow response during changing atmospheric conditions due to fixed step size and has a tendency of drifting the operating point towards the wrong side. These issues are addressed by using Incremental conductance method (INC) which has a better performance over Perturb and Observe algorithm. It has a faster response and is more efficient in tracking when the irradiance values are changing continuously. The steady-state performance of the photovoltaic control system are improved by using the MPPT algorithms.
REFERENCES:
[1] S.Mekhilef, "Performance of grid connected inverter with maximum power point tracker and power factor control, “International Journal of Power Electronics, vol. 1, pp. 49-62, 2008.
[2] Shridhar Sholapur, K. R. Mohan, T. R. Narsimhegowda,” Boost Converter Topology for PV System with Perturb And Observe MPPT Algorithm”,” IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE), Volume 9, Issue 4 Ver. II (Jul – Aug. 2014), PP 50-56.
[3] Pallavi Bharadwaj, Vinod John, “Direct Duty Ratio Controlled MPPT Algorithm for Boost Converter in Continuous and Discontinuous Modes of Operation” Indian Institute of Science Bangalore, India.
[4] Hyeonah Park, Hyosung Kim,” PV cell modeling on single-diode equivalent circuit”.
[5] Bijit Kumar Dey, Imran Khan, Nirabhra Mandal, Ankur Bhattacharjee,” Mathematical Modelling and Characteristic analysis of Solar PV Cell”, Institute of Engineering & Management Kolkata, India.

Friday, 6 March 2020

Low Switching Frequency Based Asymmetrical Multilevel Inverter Topology With Reduced Switch Count


ABSTRACT:
The inceptions of multilevel inverters (MLI) have caught the attention of researchers for medium and high power applications. However, there has always been a need for a topology with a lower number of device count for higher efficiency and reliability. A new single-phase MLI topology has been proposed in this paper to reduce the number of switches in the circuit and obtain higher voltage level at the output. The basic unit of the proposed topology produces 13 levels at the output with three dc voltage sources and eight switches. Three extentions of the basic unit have been proposed in this paper. A detailed analysis of the proposed topology has been carried out to show the superiority of the proposed converter with respect to the other existing MLI topologies. Power loss analysis has been done using PLECS software, resulting in a maximum efficiency of 98.5%. Nearest level control (NLC) pulse-width modulation technique has been used to produce gate pulses for the switches to achieve better output voltage waveform. The various simulation results have been performed in the PLECS software and a laboratory setup has been used to show the feasibility of the proposed MLI topology.
KEYWORDS:
1.      DC/AC converter
2.      Multilevel inverter
3.      Reduce switch count
4.      Nearest level control (NLC)

SOFTWARE: MATLAB/SIMULINK
CIRCUIT DIAGRAM:




Figure 1. Basic unit of the proposed topology.

 EXPERIMENTAL RESULTS:



Figure 2. Simulation results with (a) dynamic change of modulation
index (b) FFT of 13 level output voltage and current with ZD10C100mH
and (c) output voltage and current waveforms with change of load from
ZD50 to ZD50C100mH.


CONCLUSION:
The paper presents a novel MLI topology with multiple extension capabilities. The basic unit of the proposed topology produces 13 levels using eight unidirectional switches and three dc voltage sources. Three different extension of the basic unit has been proposed. The performance analysis of the basic unit of the proposed topology has been done and the comparative results with some recently proposed topologies in literature have been presented in the paper. Further, a power loss analysis of the dynamic losses (switching and conduction) in the MLI has also been presented, which gives the maximum efficiency of the basic unit as 98.5%. The power loss distribution in all the switches for different combination of loads have also been demonstrated in the paper. The performance of the proposed topology has been simulated with dynamic modulation indexes and different combination of loads using PLECS software. A prototype of the basic unit has been developed in the laboratory and the simulation results have been validated using the different experimental results considering different modulation indexes.

REFERENCES:
[1] S. Kouro, M. Malinowski, K. Gopakumar, J. Pou, L. G. Franquelo, B.Wu, J. Rodriguez, M. A. Perez, and J. I. Leon, ``Recent advances and industrial applications of multilevel converters,'' IEEE Trans. Ind. Electron., vol. 57, no. 8, pp. 2553_2580, Aug. 2010.
[2] H. Aburub, J. Holtz, and J. Rodriguez, ``Medium-voltage multilevel converters-state of the art, challenges, and requirements in industrial applications,'' IEEE Trans. Ind. Electron, vol. 57, no. 8, pp. 2581_2596, Dec. 2010.
[3] H. Akagi, ``Multilevel converters: Fundamental circuits and systems,'' Proc. IEEE, vol. 105, no. 11, pp. 2048_2065, Nov. 2017.
[4] J. I. Leon, S. Vazquez, and L. G. Franquelo, ``Multilevel converters: Control and modulation techniques for their operation and industrial applications,'' Proc. IEEE, vol. 105, no. 11, pp. 2066_2081, Nov. 2017.
[5] J. Venkataramanaiah, Y. Suresh, and A. K. Panda, ``A review on symmetric, asymmetric, hybrid and single DC sources based multilevel inverter topologies,'' Renew. Sustain. Energy Rev., vol. 76, pp. 788_812, Sep. 2017.

A Novel Multilevel DC/AC Inverter Based on Three-Level Half Bridge With Voltage Vector Selecting Algorithm



ABSTRACT:
A novel multilevel inverter based on a three-level half bridge is proposed for the DC/AC applications. For each power cell, only one DC power source is needed and five-level output AC voltage is realized. The inverter consists of two parts, the three-level half bridge, and the voltage vector selector, and each part consists of the four MOSFETs. Both positive and negative voltage levels are generated at the output, thus, no extra H-bridges are needed. The switches of the three-level half bridge are connected in series, and the output voltages are (Vo, Vo/2, and 0). The voltage vector selector is used to output minus voltages (ô€€€Vo and ô€€€Vo/2) by different conducting states. With complementary working models, the voltages of the two input capacitors are balanced. Besides, the power cell is able to be cascaded for more voltage levels and for higher power purpose. The control algorithm and two output strategies adopted in the proposed inverter are introduced, and the effectiveness is verified by simulation and experimental results.
KEYWORDS:
1.      Bridge circuits
2.      DC-AC power converters
3.      Modular multilevel converters
4.      Pulse width modulation converters
5.      Voltage control

SOFTWARE: MATLAB/SIMULINK

CIRCUIT DIAGRAM:



Figure 1. The proposed hybrid ZVS bidirectional DC/AC inverter topology.

EXPERIMENTAL RESULTS:



Figure 2. Waveforms with LFF strategy.



Figure 3. Waveforms with HFSPWM strategy.





Figure 4. Voltages of input capacitors C1 and C2.




Figure 5. Output waveforms of 2-level cascaded topologies.

CONCLUSION:
A novel multilevel inverter based on a three-level half bridge is proposed for DC/AC applications in this paper. For each power cell, only one DC power source is needed and 5-level output AC voltage is realized. Both positive and negative voltage levels are generated at the output, thus no extra H bridges are needed. The non-isolated topology (transformerless) eliminates magnetic losses. The operating principle and the working stages of the proposed inverter are introduced, while the two output strategies are discussed in detail. Besides, voltage balance strategy is adopted to balance the bus capacitor voltages, and stage optimization method is applied to further reduce the switching losses. Finally, a simulation is carried out to verify the two output strategies, voltage balance strategy and the cascaded ability, and a laboratorial experiment is carried out to test the THD losses and the total efficiency.
REFERENCES:
[1] A. Jahid, M. K. H. Monju, M. E. Hossain, and M. F. Hossain, ``Renewable energy assisted cost aware sustainable off-grid base stations with energy cooperation,'' IEEE Access, vol. 6, pp. 60900_60920, Oct. 2018.
[2] S. Xie, W. Zhong, K. Xie, R. Yu, and Y. Zhang, ``Fair energy scheduling for vehicle-to-grid networks using adaptive dynamic programming,'' IEEE Trans. Neural Netw. Learn. Syst., vol. 27, no. 8, pp. 1697_1707, Aug. 2016.
[3] A. Garcia-Bediaga, I. Villar, A. Rujas, and L. Mir, ``DAB modulation schema with extended ZVS region for applications with wide input/output voltage,'' IET Power Electron., vol. 11, no. 13, pp. 2109_2116, Nov. 2018.
[4] G. Xu, D. Sha, Y. Xu, and X. Liao, ``Hybrid-bridge-based DAB converter with voltage match control for wide voltage conversion gain application,'' IEEE Trans. Power Electron., vol. 33, no. 2, pp. 1378_1388, Feb. 2017.
[5] Y. Cho, W. Cha, J. Kwon, and B. Kwon, ``High-efficiency bidirectional DAB inverter using a novel hybrid modulation for stand-alone power generating system with low input voltage,'' IEEE Trans. Power Electron., vol. 31, no. 6, pp. 4138_4147, Jun. 2015.