asokatechnologies@gmail.com 09347143789/09949240245

Search This Blog

Friday 16 December 2016

Active Power Management of MultiHybrid Fuel Cell/Supercapacitor Power Conversion System in a Medium Voltage Microgrid




ABSTRACT:

This paper proposes a hierarchical active power management strategy for a medium voltage (MV) islanded microgrid including a multihybrid power conversion system (MHPCS). To guarantee excellent power management, a modular power conversion system is realized by parallel connection of small MHPCS units. The hybrid system includes fuel cells (FC) as main and supercapacitors (SC) as complementary power sources. The SC energy storage compensates the slow transient response of the FC stack and supports the FC to meet the grid power demand. The proposed control strategy of the MHPCS comprises three control loops; dc-link voltage controller, power management controller, and load current sharing controller. Each distributed generation (DG) unit uses an adaptive proportional resonance (PR) controller for regulating the load voltage, and a droop control strategy for average power sharing among the DG units. The performance of the proposed control strategy is verified by using digital time-domain simulation studies in the PSCAD/EMTDC software environment.

KEYWORDS:
1.      Fuel cell (FC)
2.       Multihybrid power conversion system (MHPCS)
3.       MV microgrid
4.       Supercapacitor (SC)

SOFTWARE: MATLAB/SIMULINK

CIRCUIT DIAGRAM:



Fig. 1. (a) MV microgrid consisting of two DG units. (b) Proposed structure
of hybrid FC/SC power conversion system.

CONTROL SYSTEM:



                                                                 Fig. 2. Proposed structure of the hybrid FC/SC power source.



EXPECTED SIMULATION RESULTS:



Fig. 3. Balanced load changes in feeders F3 and  F1. (a) Instantaneous real and
(b) instantaneous reactive powers of the feeders.




Fig. 4. Instantaneous voltages at the DG unit terminals during balanced load
changes in feeder F1, (a) DG1 and (b) DG2 .



Fig. 5. Frequency of islanded microgrid during balanced load changes.




Fig. 6. Dynamic response of the DG units to balanced load changes: (a) real
power, and (b) reactive power components.



Fig. 7. Dynamic response of DG1 units to balanced load changes: (a) FC
stack and SC module power of first hybrid unit; (b) FC stack and SC module
power of second hybrid unit; and (c) dc-link voltage.



Fig. 8. Unbalanced load change in feeder F1. (a) Instantaneous real and (b)
instantaneous reactive powers of the feeders.



Fig. 9. Dynamic response of the DG units to unbalanced load change with
conventional PR controller: (a) real power, and (b) reactive power components




Fig. 10. Dynamic response of the DG units to unbalanced load change with
adaptive PR controller: (a) real, and (b) reactive power.



Fig. 11. Dynamic response of DG1 units to unbalanced load change: (a) FC
stack and SC module power of first hybrid unit; (b) FC stack and SC module
power of second hybrid unit; and (c) dc-link voltage.


CONCLUSION:

This paper presents a hierarchical active power management strategy for a MV islanded microgrid considering the MHPCS. The proposed strategy includes power management of the FC/SC hybrid system, current sharing among the MHPCS components, voltage control of the ac-side, and power sharing among the DG units. The SC energy storage compensates the slow transient response of the FC stack. An adaptive PR controller and a droop controller are, respectively, used to effectively regulate the load voltage and to share the average power among the DG units. The performance of the proposed control strategy in both balanced and unbalanced load switching is investigated using PSCAD/EMTDC software. The results show that the proposed strategy:
• enhances the dynamic response of the microgrid in fast transients;
• accurately shares the load current among the FC/SC hybrid units;
• robustly regulates voltage and frequency of the microgrid;
• is able to share the average power among theDGunits even under unbalanced conditions;
• effectively eliminates the low frequency transient of power components; and
• locally compensates the unbalanced loads.

REFERENCES:

[1] N. Hatziargyriou, H. Asano, R. Iravani, and C. Marnay, “Microgrids,” IEEE Power Energy Mag., vol. 5, pp. 78–94, Jul.–Aug. 2007.
[2] A. G. Madureira and J. A. P. Lopes, “Coordinated voltage support in distribution networks with distributed generation and microgrids,” IET Renew. Power Gener., vol. 3, pp. 439–454, Sep. 2009.
[3] Z. Jiang and R. Dougal, “A hybrid fuel cell power supply with rapid dynamic response and high peak-power capacity,” in Proc. IEEE APEC, 2006, pp. 1250–1255.
[4] H. Nikkhajoei and R. Lasseter, “Distributed generation interface to the certs microgrid,” IEEE Trans. Power Del., vol. 24, pp. 1598–1608, Jul. 2009.
[5] M. Zandi, A. Payman, J.Martin, S. Pierfederici, B.Davat, and F. Meibody- Tabar, “Energy management of a fuel cell/supercapacitor/battery power source for electric vehicular applications,” IEEE Trans. Veh.Technol., vol. 60, pp. 433–443, Feb. 2011.


Thursday 15 December 2016

A Control Method for Integrating Hybrid Power Source into an Islanded Microgrid through CHB Multilevel Inverter



ABSTRACT:

This paper proposes a control strategy for an islanded microgrid to effectively coordinate hybrid power source (HPS) units and to robustly control individual interfaced inverters under unbalanced and nonlinear load conditions. Cascaded H-bridge (CHB) multilevel inverters are flexibly deployed in order to enhance the power quality and redundancy. The HPS employs fuel cell (FC) as the main and super capacitors (SC) as complementary power sources. Fast transient response; high performance; and high power density are the main characteristics of the proposed HPS system. The presented control strategy consists of a power management strategy for the HPS units and a voltage control strategy for the CHB multilevel inverter. A multi proportional resonant (multi-PR) controller is employed to regulate the load voltage at unbalanced and nonlinear load conditions. The proposed multi-PR controller includes a fundamental voltage controller with harmonic compensators. Digital time domain simulation studies in the PSCADIEMTDC environment are given to verify the overall proposed system performance.

KEYWORDS:    
                                                                                                  
1.      Hybrid power source
2.       Fuel cell
3.       Supercapacitor
4.      CHB multilevel inverter
5.       Multi-PR

SOFTWARE: MATLAB/SIMULINK

CIRCUIT DIAGRAM:



Fig. I. Proposed structure of the hybrid FC/SC power source.

CONTROL SYSTEM




Fig. 2. Proposed control strategy of hybrid FC/SC power source


EXPECTED SIMULATION RESULTS:







Fig. 3. Microgrid response to unbalanced and nonlinear load changes;
(a) Instantaneous real and reactive power. (b) Positive-sequence, negativesequence,
and harmonic components of load



Fig. 4. (a) Instantaneous current waveforms, (b) switching patterns of the
output voltage, and (c) voltage waveforms of each phase of the DG unit's
CHB inverter due to the nonlinear load connection.



Fig. 5. (a) Instantaneous current waveforms, (b) switching patterns of the
output voltage, and (c) voltage waveforms of each phase of the DG unit's
CHB inverter due to the single-phase load disconnection.




Fig. 6. (a) voltage THD, and (b) voltage unbalance factor at DG unit
terminal.



Fig. 7. The dc-link voltage waveforms to the unbalanced and nonlinear
load changes.
  


Fig. 8. Dynamic response of the DG unit to load changes: currents of FC
stacks and SC units of each HPS, (a) phase a, (b) phase b, and (c) phase c.

 CONCLUSION:

This paper presents an effective control strategy for an autonomous microgrid considering the HPS and CHB multilevel inverter under unbalanced and nonlinear load conditions. The proposed strategy includes power management of the hybrid FC/SC power source and the CHB multilevel inverter voltage control. The main characteristics of the proposed HPS are high performance; high power density; fast transient response. Furthermore, a multi-PR controller is presented to regulate the voltage of the CHB multilevel inverter in the presence of unbalanced and nonlinear loads. The performance of the proposed control strategy is investigated using PSCADIEMTDC software. The results show that the proposed strategy:
• robustly regulates the voltage of the microgrid under unbalanced and nonlinear load conditions;
• reduces THD and improves power quality by using CHB multilevel inverters;
• enhances the dynamic response of the microgrid;
• accurately balances the dc-link voltage of each H-bridge cell; and
• effectively manages the power among the power sources in the HPS system.

 REFERENCES:

[l] W. Liu, J. F. Chen, T. Liang, and R. Lin, "Multicascoded sources for a high-efficiency fuel-ceU hybrid power system in high-voltage application," IEEE Trans. Power Electron., vol. 26, pp. 931-942, Mar. 2011.
[2] IEEE Recommended Practice for Electric Power Distribution for Industrial Plants. ANSIIIEEE Std. 141, 1993.
[3] IEEE Recommended Practices and Requirements for Harmonic Control in Electrical Power System. IEEE Std. 519, 1992.
[4] J. Pereda and J. Dixon, "23-level inverter for electric vehicles using a single battery pack and series active filters," IEEE Trans. Veh. Techno!., vol. 61, pp. 1043-1051, Mar. 2012.
[5] A. Ghazanfari, M. Hamzeh, H. Mokhtari, and H. Karimi, "Active power management of multihybrid fuel celIlsupercapacitor power conversion system in a medium voltage microgrid," IEEE Trans. Smart Grid, vol. 3, pp. 1903-1910, Dec. 2012.



Frequency Adaptive Fractional Order Repetitive Control of Shunt Active Power Filters



ABSTRACT:

Repetitive control which can achieve zero steady-state error tracking of any periodic signal with known integer period, offers active power filters a promising accurate current control scheme to compensate the harmonic distortion caused by nonlinear loads. However, classical repetitive control cannot exactly compensate periodic signals of variable frequency, and would lead to significant performance degradation of active power filters. In this paper a fractional order repetitive control strategy at fixed sampling rate is proposed to deal with any periodic signal of variable frequency, where a Lagrange interpolation based fractional delay filter is used to approximate the factional delay items. The synthesis and analysis of fractional-order repetitive control systems are also presented. The proposed fractional-order repetitive control offers fast on-line tuning of the fractional delay and the fast update of the coefficients, and then provides active power filters with a simple but very accurate real-time frequency adaptive control solution to the elimination of harmonic distortions under grid frequency variations. A case study of single-phase shunt active power filter is conducted. Experimental results are provided to demonstrate the validity of the proposed fractional-order repetitive control.

KEYWORDS:

1.      Active power filter
2.      Fractional order
3.       Repetitive control
4.      Frequency variation

SOFTWARE: MATLAB/SIMULINK

CIRCUIT DIAGRAM:


Fig. 1. Single-phase shunt APF connected to the grid with nonlinear load.

CONTROL SYSTEM


Fig. 2. Dual-loop control scheme for single-phase APF.

  EXPECTED SIMULATION RESULTS:
             




Fig. 3. Steady-state responses at 50Hz without APF: (a) grid voltage vg and grid current ig, (b) harmonic spectrum of vg, (c) harmonic spectrum of ig.


Fig. 5. Steady-state responses at 50Hz with CRC controlled APF: (a) grid voltage vg and grid current ig, (b) harmonic spectrum of compensated ig.

Fig. 4. Steady-state responses at 49.8Hz with CRC controlled APF: (a) grid voltage vg and grid current ig, (b) compensation current ic, reference current iref and current tracking error, (c) harmonic spectrum of ig.

Fig. 5. Steady-state responses at 49.8Hz with FORC controlled APF: (a) grid voltage vg and grid current ig, (b) compensation current ic, reference current iref and current tracking error, (c) harmonic spectrum of ig.

Fig. 6. Steady-state responses at 50.2Hz with CRC controlled APF: (a) grid voltage vg and grid current ig, (b) compensation current ic, reference current iref and current tracking error, (c) harmonic spectrum of ig.

Fig. 7. Steady-state responses at 50.2Hz with CRC controlled APF: (a) grid voltage vg and grid current ig, (b) compensation current ic, reference current iref and current tracking error, (c) harmonic spectrum of ig.

Fig. 8. Responses to step changes of grid frequency: (a) 49.5Hz50.5Hz, (b)
50.5Hz49.5Hz.

Fig. 9. Responses to step load changes at 49.8Hz fundamental frequency: (a) R 15Ω→30Ω, (b) R 30Ω→15Ω.

CONCLUSION:

This paper proposes a frequency adaptive FORC scheme with fixed sampling rate to track or eliminate any periodic signal with variable frequency. Using Lagrange interpolation based FD filter to approximate the fractional delay items in RC, the proposed FORC offers fast on-line tuning of the fractional delay and the fast update of the coefficients. It provides APFs with a simple but very accurate real-time frequency adaptive control solution to harmonics distortions compensation under grid frequency variations. The stability criteria of FORC systems are given, which are compatible with those of CRC systems. A study case of FORC based single-phase shunt APF is done. Experiment results show the effectiveness of the proposed FORC strategy. Furthermore, the Lagrange interpolation based FORC can be used in extensive applications, such as the feeding currents control of grid connected converters [10]-[11], [27], programmable AC power supply [28], active noise cancelation, and so on.

REFERENCES:

[1] H. Akagi, “New trends in active filters for power conditioning,” IEEE Trans. Ind. Applicat., vol. 32, no. 6, pp. 1312-1322, Nov./Dec. 1996.
[2] H. Akagi, “Active harmonic filters,” Proceedings of the IEEE, vol. 93, no. 12, pp. 2128-2141, Dec. 2005.
[3] Y. Han, L. Xu, M. M. Khan, C. Chen, G. Yao, and L. Zhou, “Robust deadbeat control scheme for a hybrid APF with resetting filter and ADALINE-based harmonic estimation algorithm,” IEEE Trans. Ind. Electron., vol. 58, no. 9, pp. 3893-3904, Sep. 2011.
[4] M. Angulo, D. A. Ruiz-Caballero, J. Lago, M. L. Heldwein, and S. A. Mussa, “Active power filter control strategy with implicit closed-loop current control and resonant controller,” IEEE Trans. Ind. Electron., vol. 60, no. 7, pp. 2721-2730, Jul. 2013.

[5] P. Mattavelli and F. P. Marafao, “Repetitive-based control for selective harmonic compensation in active power filters,” IEEE Trans. Ind. Electron., vol. 51, no. 5, pp. 1018-1024, Oct. 2004.