Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid



ABSTRACT:  
The analysis of the small-signal stability of conventional power systems is well established, but for inverter based microgrids there is a need to establish how circuit and control features give rise to particular oscillatory modes and which of these have poor damping. This paper develops the modeling and analysis of autonomous operation of inverter-based microgrids. Each sub-module is modeled in state-space form and all are combined together on a common reference frame. The model captures the detail of the control loops of the inverter but not the switching action. Some inverter modes are found at relatively high frequency and so a full dynamic model of the network (rather than an algebraic impedance model) is used. The complete model is linearized around an operating point and the resulting system matrix is used to derive the eigenvalues. The eigenvalues (termed “modes”) indicate the frequency and damping of oscillatory components in the transient response. A sensitivity analysis is also presented which helps identifying the origin of each of the modes and identify possible feedback signals for design of controllers to improve the system stability. With experience it is possible to simplify the model (reduce the order) if particular modes are not of interest as is the case with synchronous machine models. Experimental results from a microgrid of three 10-kW inverters are used to verify the results obtained from the model.
KEYWORDS:
1.      Inverter
2.      Inverter model
3.      Microgrid
4.      Power control
5.      Small-signal stability
SOFTWARE: MATLAB/SIMULINK
BLOCK DIAGRAM:



Fig. 1. Typical structure of inverter-based microgrid.

 EXPECTED SIMULATION RESULTS:



Fig. 2. Active power (filtered) response of micro-sources with 3.8 kW of step
change in load power at bus 1.


Fig. 3. Reactive power exchange between the micro sources with 3.8 kW of
step change in load power at bus 1 (Initial values: Q1 =0, Q2 = 􀀀200, Q3 =
+200; Final values: Q1 = +600, Q2 = 􀀀300, Q3 = 􀀀200).


Fig. 4. Active power (filtered) response of micro-sources with 16.8 kW and
12 kVAR RL load step change at bus 1.


Fig. 5. Reactive power (filtered) response of micro-sources with 16.8 kW and
12 kVAR RL load step change at bus 1.


Fig. 6. Output voltage (d-axis) response with 27 kW of step change in load
power at bus 1.


Fig. 7. Inductor current (d-axis) response with 27 kW of step change in load
power at bus 1.


CONCLUSION:

In this paper, a small-signal state-space model of a microgrid is presented. The model includes inverter low frequency dynamics dynamics, high frequency dynamics, network dynamics, and load dynamics. All the sub-modules are individually modeled and are then combined on a common reference frame to obtain the complete model of the microgrid.
The model was analyzed in terms of the system eigenvalues and their sensitivity to different states. With the help of this analysis the relation between different modes and system parameters was established. It was observed that the dominant low-frequency modes are highly sensitive to the network configuration and the parameters of the power sharing controller of the micro sources. The high frequency modes are largely sensitive to the inverter inner loop controllers, network dynamics, and load dynamics.
Results obtained from the model were verified experimentally on a prototype microgrid. It was observed that the model successfully predicts the complete microgrid dynamics both in the low and high frequency range.
Small signal modeling has had a long history of use in conventional power systems. The inverter models (and the inclusion of network dynamics) illustrated in this paper allow microgrids to be designed to achieve the stability margin required of reliable power systems.
 REFERENCES:

[1] R. H. Lasseter, “Microgrids,” in Proc. Power Eng. Soc.Winter Meeting, Jan. 2002, vol. 1, pp. 305–308.
[2] A. Arulapalam, M. Barnes, A. Engler, A. Goodwin, and N. Jenkins, “Control of power electronic interfaces in distributed generation microgrids,” Int. J. Electron., vol. 91, no. 9, pp. 503–523, Sep. 2004.
[3] R. Lassetter, “Integration of Distributed Energy Resources: The CERTS Microgrid Concept,” CERT Rep., Apr. 2002.
[4] M. S. Illindala, P. Piagi, H. Zhang, G. Venkataramanan, and R. H. Lasseter, “Hardware Development of a Laboratory-Scale Microgrid Phase 2: Operation and Control of a Two-Inverter Microgrid,” Nat. Renewable Energy Rep., Mar. 2004.
[5] Y. Li, D. M. Vilathgamuwa, and P. C. Loh, “Design, analysis and realtime testing of a controller for multibus microgrid system,” IEEE Trans. Power Electron., vol. 19, no. 5, pp. 1195–1204, Sep. 2004.

Saturday 4 May 2019

Grid to Vehicle and Vehicle to Grid Energy Transfer using Single-Phase Bidirectional ACDC Converter and Bidirectional DC – DC converter



 ABSTRACT:

In this paper, a configuration of a single-phase bidirectional AC-DC converter and bidirectional DC-DC converter is proposed to transfer electrical power from the grid to an electrical vehicle (EV) and from an EV to the grid while keeping improved power factor of the grid. In first stage, a 230 V 50 Hz AC supply is converted in to 380V dc using a single-phase bidirectional AC-DC converter and in the second stage, a bidirectional buck–boost dc-dc converter is used to charge and discharge the battery of the PHEV (Plug-in Hybrid Electric Vehicle). In discharging mode, it delivers energy back to the grid at 230V, 50 Hz. A battery with the charging power of 1.2 kW at 120V is used in PHEV. The buck-boost DC-DC converter is used in buck mode to charge and in a boost mode to discharge the battery. A proportional-integral (PI) controller is used to control the charging current and voltage. Simulated results validate the effectiveness of proposed algorithm and the feasibility of system.
KEYWORDS:
1.      Plug-in Hybrid Electric Vehicle (PHEV)
2.      Bidirectional AC-DC Converter
3.      DC-DC Converter
4.      Vehicle to grid (V2G)
5.      Electric drive vehicle (EDVs)

SOFTWARE: MATLAB/SIMULINK

CIRCUIT DIAGRAM:




Fig.1 Proposed configuration for V2G and G2V Energy transfer




EXPECTED SIMULATION RESULTS:






Fig.2 Charging and discharging of PHEV battery (Full profile)

                                                                                    



Fig.3 Charging and discharging of PHEV battery (in large view)





Fig.4. Discharging and Charging of PHEV battery demonstrating unity
Power factor operation



Fig.5 Waveform and harmonics spectrum of the discharging grid current



Fig.6 Waveform and harmonics spectrum of the Charging grid current


CONCLUSION:
The proposed converter has delivered the AC current to/and from the grid at unity power factor and at very low current harmonics which ultimately prolongs the life of the converter and the battery and minimizes the possibility of distorting the grid voltage. It also enables V2G interactions which could be utilized to improve the efficiency of the grid.
REFERENCES:
[1] Young-Joo Lee, Alireza Khaligh, and Ali Emadi, “Advanced Integrated Bidirectional AC/DC and DC/DC Converter for Plug-In Hybrid Electric Vehicles,” IEEE Trans. on Vehicular Tech. vol. 58, no. 8, pp. 3970-3980, Oct, 2009.
[2] Bhim Singh, Brij N. Singh, Ambrish Chandra, Kamal Al-Haddad, Ashish Pandey and Dwarka P. Kothari, “A review of single-phase improved power quality ac–dc converters,” IEEE Trans. Industrial Electronics, vol. 50, no. 5, pp. 962-981, Oct. 2003.
[3] M.C. Kisacikoglu, B. Ozpineci and L.M. Tolbert, "Examination of a PHEV bidirectional charger system for V2G reactive power compensation," in Proc. of Twenty-Fifth Annual IEEE Applied Power Electronics Conference and Exposition (APEC), 2010, 21-25 Feb.2010, pp.458-465.
[4] M.C. Kisacikoglu, B. Ozpineci and L.M. Tolbert, “Effects of V2G reactive power compensation on the component selection in an EV or PHEV bidirectional charger," in Proc. of Energy Conversion Congress and Exposition (ECCE), 2010 IEEE, 12-16 Sept. 2010, pp.870-876.
[5] W. Kempton and J. Tomic, “Vehicle-to-grid power fundamentals: Calculating capacity and net revenue,” J. Power Sources, vol. 144, no. 1, pp. 268–279, Jun. 2005.

Single-Phase AC/AC Buck-Boost Converter with Single-Phase Matrix Topology



 ABSTRACT:

This paper deals with a new family of single-phase AC/AC buck-boost converter based on singlephase matrix topology. The proposed converter provides a wider range of output AC voltage in which the output voltage can be bucked and in-phase/out-of-phase with the input voltage; and the output voltage can be boosted and in-phase/out-of-phase with the input voltage. A commutation strategy is employed to realize snubberless operation. The operating principles, circuit analysis and experimental results based on TMS320F2812 DSP are presented.

KEYWORDS:
1.       Z-source converter
2.       Single-phase matrix converter (SPMC)
3.      PWM AC/AC converter


SOFTWARE: MATLAB/SIMULINK

 BLOCK DIAGRAM:



Fig. 1: Proposed topology.

 EXPECTED SIMULATION RESULTS:






(a) Buck in-phase






                                                                                (b) Buck out-of-phase

Fig. 2: Experimental results for buck mode with Vi = 70 Vrms/60Hz, D = 0.3. (a) Region (I) (buck inphase).
(b) Region (III) (buck out-of-phase). Top: vi; Bottom: vo. (x-axis: 10ms/div., y-axis: 100V/div)


(a) Boost in-phase


(b) Boost out-of-phase

Fig. 3: Experimental results for boost mode with Vi = 50 Vrms/60Hz, D = 0.7. (a) Region (II) (boost
in-phase). (b) Region (IV) (boost out-of-phase). Top: vi; Bottom: vo. (x-axis: 10ms/div., y-axis:
100V/div)

CONCLUSION:
In this paper a new family of single-phase Z-source AC/AC buck-boost converter based on singlephase matrix converter topology has been presented. The proposed converter has following fertures:the output voltage can be bucked-boosted and in-phase with the input voltage; the output voltage can be bucked-boosted and out-of-phase with the input voltage. In order to provide a continuous current path, the safe-commutation strategy is employed. Steady-state analysis and experimental results were illustrated. By duty-ratio control, the proposed converter becomes “solid-state transformers” with a continuously variable turn ratio. The proposed converter can be used as dynamic voltage restorer (DVR) to compensate voltage sags and swells in AC/AC line conditioning without any energy-storage devices requirement. The feature which the output voltage is bucked-boosted and in-phase with the input voltage is used for voltage sag compensation. The feature which the output voltage is bucked boosted and out-of-phase with the input voltage is used for voltage swell compensation.

REFERENCES:
[1] Fang X. P., Qian Z. M., Peng F. Z.: Single-phase Z-source PWM AC-AC converters, IEEE Power Electronics Letters, vol. 3, no. 4, 2005, pp. 121-124.
[2] Tang Y., Xie S., Zhang C.: Z-source AC-AC converters solving commutation problem, IEEE Trans. Power Electronics, vol. 22, no. 6, 2007, pp. 2146-2154.
[3] Kwon B. H., Mim B. D., Kim J. H.: Novel commutation technique of AC-AC converters, IEE Proc. Electr. Power Appl., vol. 145, no. 4, July 1998, pp. 295-300.
[4] Wheeler P. W., Rodriguez J., Clare J. C., Empringham L., Weinstein A.: Matrix converter: a technology review, IEEE Trans. on Ind. Electronics, vol. 49, no. 2, April 2002, pp. 276-288.
[5] Nguyen M. K., Jung Y. G., and Lim Y. C.: Single-phase Z-source buck-boost matrix converter, in proc. Of IEEE Applied Power Electronics Conference and Exposition, APEC’09, pp. 846-850, 2009.

Nine-level Asymmetrical Single Phase Multilevel Inverter Topology with Low switching frequency and Reduce device counts



ABSTRACT:


This paper presents a new asymmetrical singlephase multilevel inverter topology capable of producing ninelevel output voltage with reduce device counts. In order to obtain the desired output voltage, dc sources are connected in all the combination of addition and subtraction through different switches. Proposed topology results in reduction of dc source, switch counts, losses, cost and size of the inverter. Comparison between the existing topologies shows that the proposed topology yields less component counts. Proposed topology is modeled and simulated using Matlab-Simulink software in order to verify the performance and feasibility of the circuit. A low frequency switching strategy is also proposed in this work. The results show that the proposed topology is capable to produce a nine-level output voltage with less number of component counts and acceptable harmonic distortion content.
KEYWORDS:

1.      Multilevel inverter
2.      Asymmetrical
3.      Total Harmonic Distortion (THD)
4.      Low-frequency switching

SOFTWARE: MATLAB/SIMULINK

 BLOCK DIAGRAM:








Fig. 1. Proposed nine level inverter topology.


 EXPECTED SIMULATION RESULTS:



Fig. 2. Simulation results for proposed nine level inverter topology; (a)
and (b) are switching pulses, (c) Level generator output voltage.





Fig. 3. Simulation Output results at 50Hz fundamental frequency for R = 150ohm, L= 240, P.F = 0.9

Fig. 4. Simulation Output results at 50Hz fundamental frequency for R =150ohm, L= 240, P.F = 0.9

CONCLUSION:
In this paper a new single-phase multilevel inverter topology is presented. Proposed topology is capable of producing nine-level output voltage with reduce device counts. It can be used in medium and high power application with unequal dc sources. Different modes of operation are discussed in detail. On the bases of device counts, the proposed topology is compared with conventional as well as other asymmetrical nine-level inverter topologies presented in literature. Comparative study shows that, for nine level output, the proposed topology requires lesser component counts then the conventional and other topologies. Proposed circuit is modeled in Matlab/Simulink environment. Results obtained shows that topology works properly. Detailed Simulation analysis is carried out. THD obtained in the output voltage is 8.95% whereas the each harmonic order is < 5%, satisfies harmonic Standard (IEEE-519).

REFERENCES:
[1] J. Rodriguez, L. G. Franquelo, S. Kouro, J. I. Leon, R. C. Portillo, M. A.M. Prats and M. A. Perez, “Multilevel Converters: An Enabling Technology for High-Power Applications”, IEEE Proceeding, Vol 97, No. 11, pp.1786 – 1817, November 2009.
[2] J. R. Espinoza, “Inverter”, Power Electronics Handbook, M. H. Rashid, Ed. New York, NY, USA: Elsevier, 2001,pp. 225 -269.
[3] L. M. Tolbert and T. G. Habetler, “Novel multilevel inverter carrierbased PWM method”, IEEE Transactions on Indsutrial Apllications”, Vol. 35, No. 5, pp. 1098-1107, September 1999.
[4] S. Debnath, J. Qin, B. Bahrani, M. Saeedifard and P. Barbosa, “Operation, Control and Applications of the Modular Multilevel Converter: A Review”, IEEE Transactions on Power Electronics, Vol. 30, No. 1, pp. 37-53, January 2015.
[5] L. G. Franquelo, J. Rodriguez, J. I. Leon, S. Kouro, R. C. Portillo and M. A. M. Prats, “The Age of Multilevel Converters Arrives”, IEEE Industrial Electronics magazine, Vol. 2, No. 2 pp. 28-39, June 2008.

Friday 3 May 2019

Operation and Control of Smart Transformer for Improving Performance of Medium Voltage Power Distribution System



 ABSTRACT:  
Smart transformer (ST) is a power electronic based transformer equipped with effective control and communication. It is expected to play a significant role in future power distribution system, however, their operational features in the medium voltage (MV) power distribution systems are yet not explored. In this paper, operation and control of ST are presented for improving its performance and operational range in a power distribution system consisting of two radial feeders in a city center. For investigating the performance of ST in above system, one conventional power transformer (CPT) is replaced by the ST whereas other feeder is continued to be supplied through the CPT. In this scheme, the ST is operated such that it makes total MV grid currents of the combined system balanced sinusoidal with unity power factor. Therefore, in addition to providing continuous and reliable operation of ST based loads, the ST can also improve the performance of the loads which are supplied by the CPT in a different feeder. Moreover, the proposed scheme eliminates the need of power quality improvement devices at the other feeder. Therefore, the scheme also makes the application of ST in the distribution system cost effective. Simulation results validate the suitability of ST in improving the performance of multiple feeder medium voltage power distribution system.
KEYWORDS:
1.      Smart transformer (ST)
2.      Medium voltage rectifier
3.      Power distribution system

SOFTWARE: MATLAB/SIMULINK
BLOCK DIAGRAM:




Fig. 1. A schematic of conventional power distribution system consisting of
two radial feeders in a city center.

 EXPECTED SIMULATION RESULTS:




Fig. 2. Simulated waveforms when ST is not compensating for feeder II. (a) PCC voltages. (b) Grid currents. (c) MV rectifier currents (d) Feeder II currents.



Fig. 3. Simulated waveforms when ST is compensating for feeder II. (a) PCC voltages. (b) Grid currents. (c) MV rectifier currents (d) Feeder II currents.



Fig. 4. Simulated waveforms during transient conditions when load in feeder II is changed. (a) PCC voltages. (b) Grid currents. (c) MV rectifier currents (d) Feeder II currents.


CONCLUSION:

In this paper, the operation and control of a futuristic power distribution system consisting of two radial feeders with one CPT replaced by an ST is presented. It is shown that the ST can compensate for the loads connected at the feeder supplied by the CPTs, in addition to supplying their own loads. This scheme has potential to eliminate the requirement of power quality improvement devices such as STATCOM, power factor correcting capacitors, etc., connected at the second feeder. This ancillary feature in the medium voltage power distribution systems has potential to make application of ST more attractive and cost effective.
REFERENCES:
[1] S. Bifaretti, P. Zanchetta, A. Watson, L. Tarisciotti, and J. Clare, “Advanced power electronic conversion and control system for universal and flexible power management,” Smart Grid, IEEE Transactions on, vol. 2, no. 2, pp. 231–243, Jun. 2011.
[2] X. She, R. Burgos, G. Wang, F. Wang, and A. Huang, “Review of solid state transformer in the distribution system: From components to field application,” in Energy Conversion Congress and Exposition (ECCE),
2012 IEEE, Sep. 2012, pp. 4077–4084.
[3] S. Alepuz, F. Gonzalez, J. Martin-Arnedo, and J. Martinez, “Solid state transformer with low-voltage ride-through and current unbalance management capabilities,” in Industrial Electronics Society, IECON 2013 - 39th Annual Conference of the IEEE, Nov. 2013, pp. 1278–1283.
[4] S.-H. Hwang, X. Liu, J.-M. Kim, and H. Li, “Distributed digital control of modular-based solid-state transformer using dsp+fpga,” Industrial Electronics, IEEE Transactions on, vol. 60, no. 2, pp. 670–680, Feb. 2013.