Comparison of Controllers for
Power Quality Improvement Employing Shunt Active Filter
ABSTRACT:
In
this paper, an implementation of shunt active filter for current harmonics
compensation in order to achieve power quality improvement under non linear
load condition is proposed. Shunt active filter makes the source current almost
sinusoidal under non linear load condition by eliminating current harmonics.
Controller generates the reference current and it is compared with actual
current. PWM current controller controls the switch of the shunt active filter
circuit. Shunt active filter eliminates the undesired current harmonics by injecting
current into the system thereby reduces total harmonic distortion and improves
power factor. The main objective of the project is to find the most suitable
control method that is capable of reducing total harmonic distortion in the
source current under non linear load condition. Fast and precise control loop
is needed in order to assure the desired power quality. Three control
techniques have been proposed: PI controller, Hysteresis current controller, Fuzzy
logic controller. The system is modeled using Matlab/Simulink and simulation
results prove that the source current harmonics can be reduced and power factor
can be improved. The comparative performance of the proposed three controllers
is also presented.
KEYWORDS:
1. Power
Quality
2. Shunt
Active Filter
3. Voltage
Source Inverter
4. PI
5. Hysteresis
Current Controller
SOFTWARE: MATLAB/SIMULINK
BLOCK DIAGRAM:
EXPECTED SIMULATION
RESULTS:
CONCLUSION:
In
this paper, the design of shunt active filter to compensate harmonics in the
power system based on three control techniques were presented and compared. All
the control techniques make the source voltage and source current to be in
phase. In the first control scheme the capacitor voltage is regulated based on
reference voltage and provides compensation for the reduction of harmonics in
the source current, the second one provides compensation based on reference
current generated from the fourier transform of load current, while the third
one considers the active filter controlled by fuzzy logic controller which is
suitable for uncertainty condition. Among the three proposals the fuzzy logic
control technique [7] doesn't need any mathematical model,
reduces total harmonic distortion in a better way and provides good performance
and robust to the parameter uncertainties compared with other strategies.
REFERENCES:
[1]
David A .Torrey, Adel M. A . M. AI-Zamel "Single-phase active power filters
for multiple nonlinear loads" IEEE Transactions on Power Electronics, Vol.
1 0, No. 3, May 1 995, pp 263-2 72.
[2]
B.Singh ,K.Ai-Haddad, and A.chandra , " A review of active filters for power
quality improvement" IEEE Transaction on Industrial electronics, vol
46,Issue no. 5, Oct-1999, pp 960-971.
[3]
Fabiana Pottker de Souza, and Ivo Barbi, " Single-phase active power filters
for distributed power factor correction", Power Electronics Specialists
Conference 2000, PESC 00, Vol.l , pp500-505.
[4]
M. EI- Habrouk, M.K. Darwish and P. Mehta "Active filter - A review" Electric
Power Applications, lEE Proceedings, Vol 1 4 7, Sep 2000, Issue 5, pp 403-413.