asokatechnologies@gmail.com 09347143789/09949240245

Search This Blog

Wednesday 19 December 2018

Performance Analysis of DVR, DSTATCOM and UPQC For Improving The Power Quality With Various Control Strategies



ABSTRACT:

Here, we have studied the voltage quality improvement methods by using Dynamic Voltage Restorer (DVR), Distribution Static Synchronous Compensator (D-STATCOM) and Unified Power Quality Conditioner (UPQC) using two different controller Strategies. The controllers used are Proportional Integral Controller (PIC) and Fuzzy Logic Controller (FLC). A PI Controller calculates an error value as the difference between a measured variable and desired set point. The fuzzy logic controller has real time inputs measured at every sample time, named error and error rate and one output named actuating signal for each phase. The input signals are fuzzified and represented in fuzzy set notations as functions. The defined 'If ... Then .. .' rules produce output actuating signals and these signals are defuzzified to analog control signals for comparing with a carrier signal to control PWM inverter.

KEYWORDS:
1.      Dynamic Voltage Restorer (DVR)
2.      Distribution Static Synchronous Compensator (D-STATCOM)
3.      Unified Power Quality Conditioner (UPQC)
4.      Power Quality
5.      PI Controller
6.      Fuzzy Controller and MATLAB

SOFTWARE: MATLAB/SIMULINK

BLOCK DIAGRAM:


Fig 1. The equivalent circuit diagram of DVR


Fig 2. The equivalent circuit diagram of DST A TCOM

Fig 3.The circuit diagram of UPQC


EXPECTED SIMULATION RESULTS:



Fig 4. Input voltage and input current waveform without compensation


Fig 5. Load voltage and load current waveform without compensation


Fig 6. load voltage and load current waveform after compensation(DVR)




Fig 7. Output load voltage without compensation

Fig 8. Output load voltage with compensation using FLC

Fig 9.load voltage and load current waveform after compensation (D-STATCOM)




Fig 10. Load voltage and load current waveform after compensation (D-STATCOM)




Fig 11. Load voltage and load current waveform for UPQC with PI Controller.



Fig 12 Load voltage and load current waveform with compensation

CONCLUSION:

In this paper, we have studied the series, shunt and series shunt compensators. Performance analysis has been done by comparing the power quality using each compensator. The performance of DVR has been analyzed with PI controller the load voltage during fault is almost equal to the desired load voltage. Load current magnitude is almost equal but still there are some imbalances between the phases for a small duration of time. DVR have been found to regulate voltage under Fuzzy Logic controller. It is clear that DVR reduces harmonics from load voltage very effectively and makes it smooth. Hence, it is concluded that DVR has a huge scope in improving power quality in distribution systems. DSTATCOM is proved to compensate voltage levels under faulty conditions. Using PI controller, harmonics have been reduced considerably. But current got unbalanced for the entire duration of time. By using the Fuzzy Logic Controller instead of the PI Controller gives better transient response. The DC Link voltage is suddenly increased above the reference value. And it is brought back to its reference value. A good voltage control is also achieved by implementing Fuzzy logic control. Also the steady state is reached faster. The control strategies of UPQC were described and compared with respect to its performance through simulation. The power quality issues are almost reduced. The closed loop control schemes of current control, for the proposed UPQC have been investigated. Total harmonic distortion was analyzed and it describes that the UPQC with fuzzy controller provides more efficiency than the other strategies.

 REFERENCES:

[1] Smriti De)'. Comparison of DVR and D-STATCOM for Voltage (",)uality Improvement, [JET AE (ISSN 2250- 2459), Vol 4, Issue 10, October 2014, PP 187-193.
[2] Ganeshkumar.A, Ananthan.N, Performance Comparison Of UPQC For Improving The Power Quality With Various Controllers Strategy ,IJETCSE, Vol 13 Issue 2, March2015,PP 12-17.
[3] Shipra Pandey, Dr. S.Chatterji, Ritula Thakur. Fuzzy Controlled DSTATCOM for Voltage Sag Compensation and DC-Link Voltage Improvement. [JEECS , ,Vol 3, Issue I, April 2014.
[4] C. Sankaran "Power Quality", CRC Press 2002.
[5] N.G. Hingorani and L Gyugyi, Understanding FACTS - Concepts and Technology OF Flexible AC Transmission Systems, IEEE Press, New York, 2000.