ABSTRACT:
In the
traditional virtual flux estimation for a three-phase PWM rectifier, the
integration element causes problems for the initial value and DC bias, and the
unstable grid voltage induces a non-constant flux amplitude. To address these
issues, an improved direct power control (DPC) scheme based on an adaptive
sliding mode observer (ASMO) is proposed in this work. The observer employs a
sigmoid function as switch function to estimate the grid side source voltage.
Meanwhile, an adaptive compensator instead of pure integral element is also
designed to dynamically adjust compensation. The stability of this observer is
proved by the Lyapunov function; moreover, simulations and experimental results
indicate that this new virtual flux observer substantially improves the
observation accuracy based on voltage sensorless control. The application of
this strategy successfully suppresses the fluctuation of the dynamic voltage
response in the DC bus, eliminating high-frequency noise from the grid side,
whilst simultaneously boosting the power quality.
KEYWORDS:
1.
PWM rectifier
2.
Virtual flux
3.
Adaptive
sliding mode observer
4.
DPC
SOFTWARE: MATLAB/SIMULINK
BLOCK DIAGRAM:
Fig.
1. System structure of traditional voltage sensor-less (VF-DPC)
EXPECTED SIMULATION RESULTS:
Fig.
2. Comparison of steady-state curve under four methods.
Fig.
3. Dynamic simulation I of saturation suppression and adaptive sliding mode.
Fig.
4. Dynamic simulation II of saturation suppression and adaptive sliding mode.
Fig.
5. Dynamic simulation of traditional voltage sensorless control.
Fig.
6. Dynamic simulation of adaptive sliding mode.
Fig.
7. Comparison of bus voltage during load step.
Fig.
8. Comparison of phase current and voltage during load step.
CONCLUSION:
This
paper introduces sliding mode control in a virtual flux observer, based on the
three-phase PWM rectifier model under virtual flux DPC; moreover, the
systematic design of an orthogonal feedback compensation method to calibrate
the flux estimation has been proposed. An improved sensorless control algorithm
with an adaptive sliding mode observer has been simulated and experimentally
verified. Results show that the combination of sliding control and virtual flux
observer has improved dynamic response over traditional control strategies.
This scheme can significantly improve the observation accuracy and dynamic
response performance of the observer, and suppress the dynamic fluctuation and
harmonic disturbance, increasing the overall power quality and delivery.
REFERENCES:
[1]
J. W. Kolar, T. Friedli, J. Rodriguez, and P. W. Wheeler, “Review of
three-phase PWM AC-AC converter topologies,” IEEE Transactions on Industrial
Electronics, vol. 58, no. 11, pp. 4988–5006, Nov. 2011.
[2]
Y. Zhang, Z. Li, Y. Zhang, W. Xie, Z. Piao, and C. Hu, “Performance improvement
of direct power control of PWM rectifier with simple calculation,” IEEE
Transactions on Power Electronics, vol. 28, no. 7, pp. 3428–3437, Jul.
2013.
[3]
B. Singh, B. N. Singh, A. Chandra, K. Al-Haddad, A. Pandey, and D. P. Kothari,
“A review of three-phase improved power quality ac-dc converters,” IEEE
Transactions on Industrial Electronics, vol. 51, no. 3, pp. 641–660, Jun.
2004.
[4]
A. Rahoui, A. Bechouche, H. Seddiki and D. O. Abdeslam, “Grid Voltages
Estimation for Three-Phase PWM Rectifiers Control Without AC Voltage Sensors,” IEEE
Transactions on Power Electronics, vol. 33, no. 1, pp. 859–875, Jan. 2018.
[5] A. Bechouche,
H. Seddiki, D. Ould Abdeslam and K. Mesbah, “Adaptive AC filter parameters
identification for voltage-oriented control of three-phase voltage-source
rectifiers,” International Journal of Modelling Identification and Control,
vol. 24, no. 4, pp. 319–331, 2015.